Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EVOLUTION ROOFING CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EVOLUTION ROOFING CORP in 208 HIGHLAND AVE, MALDEN, MA 02148 (NAICS 238160). OSHA activity number 346517436.

Watch Evolution Roofing Corp — free Get an email when a new federal OSHA severe-injury report for Evolution Roofing Corp is published. One employer, no account, unsubscribe in one click.
Site address
208 HIGHLAND AVE
City
MALDEN
State
MA
ZIP
02148
Mailing
65 BILLERICA STREET, LOWELL, MA 01852
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $6250.00 · Current $6250.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer than 10-feet to exposed and energized power lines.  Location: 208 Highland Ave, Malden, MA;  On or about 02/21/2023, the employer erected and allowed employees to utilize an Alum-A-Pole pumpjack scaffolding system which was within 3-feet of energized main power lines.
Recent events (3)
  • — F (S) $6250
  • — C (S) $6250
  • — Z (S) $6250

1926.416 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $12500.00 · Current $0.00 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits that were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.  Location: 208 Highland Ave, Malden, MA  On or about 02/21/2023, employees were permitted to perform siding activities from an Alum-A-Pole pumpjack scaffolding system that was in proximity (3-feet) to exposed energized power lines.  Evolution Roofing Corp was previously cited for a violation of this occupational safety and health standard, 1926.416(a)(1), which was contained in OSHA inspection number 1542051, citation number 1, item number 1 and was affirmed as a final order on 12/01/2021, with respect to a workplace located at 660 Bridge Street, Lowell, MA.
Recent events (3)
  • — F (S) $0
  • — C (R) $12500
  • — Z (R) $12500

1926.452 J02

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $6250.00 · Current $12500.00
29 CFR 1926.452(j)(2): Poles of pump jack scaffolding were not secured to the structure by rigid triangular bracing, or equivalent, at the bottom as necessary.  Location: 208 Highland Ave, Malden, MA;  On or about 02/21/2023, the employer erected an Alum-A-Pole pumpjack scaffold and did not secure the bottoms of the four pole sections with rigid triangular bracing, or equivalent means and exposed employees to a potential fall or struck-by hazard if the poles kicked out or slid out of place on the concrete walkway which they were erected on top of.
Recent events (3)
  • — F (S) $12500
  • — C (S) $6250
  • — Z (S) $6250

1926.451 F07

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $12500.00 · Current $0.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.  Location: 208 Highland Ave, Malden, MA  On or about 02/21/2023, the employer allowed an Alum-A-Pole pumpjack scaffolding system to be erected on-site by employees who were not trained or experienced and had no competent person who was qualified in scaffold erection, moving, dismantling or alteration on-site.  Evolution Roofing Corp was previously cited for a violation of this occupational safety and health standard, 1926.451(f)(7), which was contained in OSHA inspection number 1464173, citation number 1, item number 1 and was affirmed as a final order on 05/11/2020, with respect to a workplace located at 1190 Bedford St, Whitman, MA.
Recent events (3)
  • — F (S) $0
  • — C (R) $12500
  • — Z (R) $12500

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Penalty
Initial $12500.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.  Location: 208 Highland Ave, Malden, MA  On or about 02/21/2023, employees were allowed to work on a flat roof at the rear of the residence who were not protected by any form of fall protection system.  The Evolution Roofing Corp was previously cited for a violation of this occupational safety and health standard, 1926.501(b)(13), which was contained in OSHA inspection number 1464173, citation number 1, item number 2 and was affirmed as a final order on 05/11/2020, with respect to a workplace located at 1190 Bedford St, Whitman, MA.
Recent events (3)
  • — F (S) $0
  • — C (R) $12500
  • — Z (R) $12500

1904.40 A

Other-than-serious 3 instances 6 exposed
Issued
Penalty
Initial $893.00 · Current $893.00
29 CFR 1904.40(a): The employer did not provide an authorized government representative copies of OSHA 300 logs records within the four business hours.  Location: 208 Highland Ave, Malden, MA  On or about 02/21/2023, the employer was unable to provide CSHO with any copies of OSHA 300 logs which their company is required to keep per 29 CFR 1904.01(a)(2).
Recent events (3)
  • — F (O) $893
  • — C (O) $893
  • — Z (O) $893

View EVOLUTION ROOFING CORP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346517436.