Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYKSTRA CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DYKSTRA CONSTRUCTION, INC. in 110 LYNDE AVE, BAYFIELD, WI 54814 (NAICS 238130). OSHA activity number 345424766.

Watch Dykstra Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Dykstra Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
110 LYNDE AVE
City
BAYFIELD
State
WI
ZIP
54814
Mailing
50181 STATE HIGHWAY 13, ASHLAND, WI 54806
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
16
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 21, 2021
Abate by
Oct 1, 2021
Penalty
Initial $5,461 · Current $3,823 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a)  Roof of new single-family home; Fall protection was not used while employees installed roof decking and a parapet on a low-slope, residential roof at heights ranging from 7 feet, 9 inches to 9 feet, 8 inches.
Recent events (2)
  • — I (S) $3822.7
  • — Z (S) $5461

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 21, 2021
Abate by
Oct 1, 2021
Penalty
Initial $3,901 · Current $2,731 Reduced
29 CFR  1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  (a) North side of building; An 8-foot, Louisville brand stepladder was used in the closed position, as a non-self supporting ladder, for accessing and exiting the roof.
Recent events (2)
  • — I (S) $2730.7
  • — Z (S) $3901

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 21, 2021
Abate by
Oct 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(13): The top or top step of a stepladder was used as a step:  (a) North side of building; The top step and top plate of an 8-foot, Louisville brand stepladder were used for accessing and exiting the roof.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Dykstra Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345424766.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.