GONZALES, LA —
OSHA Inspection: ESP VALVE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ESP VALVE, INC. in 41107 DON LOU DRIVE, GONZALES, LA 70737 (NAICS 332919). OSHA activity number 345428130.
Where did this inspection happen?
- Establishment
- ESP VALVE, INC.
- Site address
- 41107 DON LOU DRIVE
- City
- GONZALES
- State
- LA
- ZIP
- 70737
- Mailing
- 41107 DON LOU DRIVE, GONZALES, LA 70737
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332919
- Employees
- 10
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A01
- Issued
- Sep 30, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $3,901 · Current $2,341 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks. On or about July 20, 2021, the following equipment in the main bay/shop north side area lacked a fixed or moveable guard to protect employees from point-of-operation hazards and/or contact with rotating machine�parts on a WEB Drill Press Model # 2VK.
Recent events (2)
- — I (S) $2340.6
- — Z (S) $3901
More inspections at ESP Valve, INC.
View ESP Valve, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332919)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345428130.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.