Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNLAND CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNLAND CONSTRUCTION INC. in CORNER OF LA HWY 929 AND PARKER RD, PRAIRIEVILLE, LA 70769 (NAICS 237120). OSHA activity number 345428395.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunland Construction INC. — free Get an email when a new federal OSHA severe-injury report for Sunland Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
CORNER OF LA HWY 929 AND PARKER RD
City
PRAIRIEVILLE
State
LA
ZIP
70769
Mailing
P.O. BOX 1087, HWY 13 S., EUNICE, LA 70535
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.501 B07 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Aug 17, 2021
Penalty
Initial $9,753 · Current $0 Reduced
29 CFR  1926.501(b)(7)(ii): Each employee at the edge of a well, pit, shaft, or similar excavation 6 feet (1.8 m) or more in-depth was not protected from falling by guardrail systems, fences, barricades, or covers.   On or about July 14, 2021, employees of Sunland Construction Inc. worked around the edge of an open excavation that was over six feet in depth with no barriers, guardrails, or personal fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9753

1926.651 C

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Aug 17, 2021
Penalty
Initial $13,653 · Current $10,922 Reduced
29 CFR  1926.651(c): Means of egress from trench excavations.  A stairway, ladder, ramp, or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in-depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  On or about July 14, 2021, Southwest's side of the job site, employees observed in an excavation deeper than Four feet (4) feet in deep to install/repair a pipeline without a means of safe egress.
Recent events (2)
  • — I (O) $10922.4
  • — Z (S) $13653

1926.652 A01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Aug 17, 2021
Abate by
Aug 30, 2021
Penalty
Initial $13,653 · Current $10,922 Reduced
29 CFR 1926.652(a)(1): Each employee in the excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  On or about July 14, 2021, employees were observed in an excavation greater than five (5) feet deep, where an eight (8) foot trench shield was placed in the excavation in conjunction with "benching" and "sloping" as a protective mechanism. According to Sunland Construction, the soil was classified as type "C" soil, which does not permit benching. Additionally, on the south and east side of the excavation, the bench and sloping had an inclination degree greater than forty-five degrees. Therefore, this protective system did not provide adequate protection for employees repairing/installing a pipeline.
Recent events (2)
  • — I (O) $10922.4
  • — Z (S) $13653

1926.652 G01 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 17, 2021
Penalty
Initial $9,753 · Current $0 Reduced
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movements of the shield in the event of the application of sudden lateral loads.   On or about July 14, 2021, on the south side of the trenching area, employees worked inside an excavation greater than five (5) feet deep trench where the north side of the trench shield was not flush against the sidewall of the excavation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9753

View Sunland Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345428395.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.