BOISE, ID ·
OSHA Inspection: CAPITAL ROOFING PROS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CAPITAL ROOFING PROS LLC in 2301 S GEORGETOWN WAY, BOISE, ID 83709 (NAICS 238160). OSHA activity number 345430185.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAPITAL ROOFING PROS LLC
- Site address
- 2301 S GEORGETOWN WAY
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 302 BROOKDALE DR, BOISE, ID 83712
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 9
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 22, 2021
- Penalty
- Initial $4,096 · Current $2,867 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Residential Roof: On or about July 21, 2021, and at times prior to; employees working from a 7:12 multi-pitched roof on the first and second story were exposed to falls from 8.5 feet to 24 feet.
Recent events (2)
- · I (S) $2867.2
- · Z (S) $4096
1926.1053 B01
- Issued
- Nov 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On July 21, 2021; extension ladder used to access the first story eave and ridge cap was extended approximately two rungs above the upper landing surface.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238160)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345430185.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.