Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNRUN SOLAR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNRUN SOLAR in 29 S BEDFORD ST, WOBURN, MA 01801 (NAICS 238210). OSHA activity number 345431852.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunrun Solar — free Get an email when a new federal OSHA severe-injury report for Sunrun Solar is published. One employer, no account, unsubscribe in one click.
Establishment
SUNRUN SOLAR
Site address
29 S BEDFORD ST
City
WOBURN
State
MA
ZIP
01801
Mailing
775 FIERO LN #200 #200, SAN LUIS OBISPO, CA 93401
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
100
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 28, 2021
Abate by
Nov 3, 2021
Penalty
Initial $10,728 · Current $10,728
29 CFR  1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  29 S. Bedford St., Woburn, MA On or about, July 17, 2021, employees were exposed to being struck in the head from falling tools, equipment solar panel parts while working on the ground and from ladders below the workers installing the solar panel system on the roof.
Recent events (1)
  • — Z (S) $10728

1926.416 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 28, 2021
Abate by
Nov 3, 2021
Penalty
Initial $10,728 · Current $10,728
29 CFR  1926.416(a)(1) :Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  29 S Bedford St., Woburn, MA  On or about, July 17, 2021, employees were exposed to an electrocution hazard  while installing a solar panel system on a residential roof near an energized service drop that was not insulated, covered or guarded by insulation.
Recent events (1)
  • — Z (S) $10728

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Oct 28, 2021
Abate by
Nov 3, 2021
Penalty
Initial $75,092 · Current $75,092
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   29 S Bedford St., Woburn, On or about, July 17, 2021, employees were exposed to falls of up to 22 feet while installing a solar energy system on a residential single-family house roof without fall protection.  The Sunrun Solar, Inc. company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1342329,  citation number 1, item number 1 and was affirmed as a final order on March 12, 2019, with respect to a workplace located at 63-19 90th Street, Howard Beach, NY 11414.
Recent events (1)
  • — Z (R) $75092

1926.503 A02 II

Repeat Gravity 10 1 instance 6 exposed
Issued
Oct 28, 2021
Abate by
Dec 16, 2021
Penalty
Initial $75,092 · Current $75,092
29 CFR  1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:   29 S Bedford St., Woburn, On or about, July 17, 2021, employees were exposed to falls of up to 22 feet while installing a solar energy system on a residential single-family house roof were not adequately trained in the installation, used and limitations of the personal fall arrest and restraint equipment, anchorage installation and use, the allowable working zones to reduce the risk of swing falls and improper loading.  The Sunrun Solar, Inc. company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR  1926.503(a)(2)(ii), which was contained in OSHA inspection number 1191351,  citation number 1, item number 1B and was affirmed as a final order on January 23, 2017, with respect to a workplace located at 19 Pine Knoll Road, Southwick, MA 01077.
Recent events (1)
  • — Z (R) $75092

View Sunrun Solar's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345431852.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.