WASHINGTON, DC —
OSHA Inspection: SAMER IRON WORKS, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAMER IRON WORKS, LLC. in 2147 P STREET, NW, WASHINGTON, DC 20037 (NAICS 238120). OSHA activity number 345432421.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMER IRON WORKS, LLC.
- Site address
- 2147 P STREET, NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20037
- Mailing
- 328 NORTH STONESTREET AVENUE, ROCKVILLE, MD 20850
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 1
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.95 A
- Issued
- Jan 20, 2022
- Penalty
- Initial $2,113 · Current $2,113
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and/or maintained in a sanitary and reliable condition: a) First Floor at Stairway - Employees were exposed to eye injuries while operating a DeWalt seven inch portable hand grinder, model # DWE43116, to grind out a beam pocket without wearing impact-resistant eye protection, on or about 07/21/2021. NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $2113
1926.300 B01
- Issued
- Jan 20, 2022
- Abate by
- Jan 26, 2022
- Penalty
- Initial $2,113 · Current $2,113
General-duty citation text
29 CFR 1926.300(b)(1):Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) First floor at stairway #1 - Employee was using a DeWalt seven inch portable electric grinder, model number DWE43116 to clear out a beam pocket in a concrete masonry unit wall and the flange guard was not provided, on or about 07/21/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2113
1926.350 A09
- Issued
- Jan 20, 2022
- Abate by
- Jan 26, 2022
- Penalty
- Initial $1,585 · Current $1,585
General-duty citation text
29 CFR 1926.350(a)(9):Compressed gas cylinder(s) were not secured in an upright position: a) First Floor, West Side - An oxygen and acetylene cylinder were in storage and not secured, on or about 07/21/2021 In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1585
1926.350 A10
- Issued
- Jan 20, 2022
- Abate by
- Jan 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel gas or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1m) or by a noncombustible barrier at least 5 feet (1.5m) high having a fire-resistance rating of at least one half hour: a) First Floor, West Side - An oxygen and an acetylene cylinder were being stored approximately 3 feet apart, on or about 07/21/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Jan 20, 2022
- Penalty
- Initial $2,642 · Current $2,642
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) First Floor Elevator - Employees were installing a steel beam near an unguarded elevator shaft and exposed to a 16 foot fall hazard, on or about 07/21/2021. ABATEMENT DOCUMENTATION NOT REQUIRED
Recent events (1)
- — Z (S) $2642
1926.1053 B04
- Issued
- Jan 20, 2022
- Abate by
- Jan 26, 2022
- Penalty
- Initial $1,585 · Current $1,585
General-duty citation text
29 CFR 1926.1053(b)(4):Ladder(s) were used for purposes other than the purpose for which they were designed: a) First Floor at Stairway - Employee was standing on a Louisville portable 8 foot step ladder while grinding out a concrete masonry unit wall beam pocket and the ladder was used in the closed position and leaning up against the wall, on or about 07/21/2021. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).