OSHA Inspection: ELWARD SYSTEMS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELWARD SYSTEMS CORPORATION in 680 HARLAN ST, LAKEWOOD, CO 80214 (NAICS 332312). OSHA activity number 345444327.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Elward Systems Corporation — free Get an email when a new federal OSHA severe-injury report for Elward Systems Corporation is published. One employer, no account, unsubscribe in one click.
Site address
680 HARLAN ST
City
LAKEWOOD
State
CO
ZIP
80214
Mailing
680 HARLAN ST, LAKEWOOD, CO 80214
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
45
Ownership type
A

3 citations on file for this inspection.

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 14, 2021
Abate by
Nov 1, 2021
Penalty
Initial $6,144 · Current $6,144
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which fully enclosed that portion of the saw above the table and above the material being cut:  (a) Elward Systems Corporation at 680 Harlan St. Lakewood, CO 80214: On or before 7/28/21, the employer did not protect employees from injury in that the guard assembly including a self-adjusting hood was not installed on the Rockwell Unisaw tablesaw model 5-66, serial number KR2018 while in use by employees. This condition exposed employees to amputation hazards.  (b) Elward Systems Corporation at 680 Harlan St. Lakewood, CO 80214: On or before 7/28/21, the employer did not protect employees from injury in that the guard assembly including a spreader / riving knife was not installed on the Rockwell Unisaw tablesaw model 5-66, serial number KR2018 while in use by employees. This condition exposed employees to kickback hazards.  (c) Elward Systems Corporation at 680 Harlan St. Lakewood, CO 80214: On or before 7/28/21, the employer did not protect employees from injury in that the guard assembly including non-kickback fingers or dogs were not installed on the Rockwell Unisaw tablesaw model 5-66, serial number KR2018 while in use by employees. This condition exposed employees to amputation hazards.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (3)
  • — F (S) $6144
  • — C (S) $6144
  • — Z (S) $6144

1910.213 C02

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 14, 2021
Abate by
Nov 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   (a) Elward Systems Corporation at 680 Harlan St. Lakewood, CO 80214: On or before 7/28/21 the employer did not protect employees from injury in that the guard assembly including a spreader / riving knife was not installed on the Rockwell Unisaw tablesaw [model: 5-66, serial number: KR2018] while in use by employees. This condition exposed employees to kickback hazards.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.213 C03

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Sep 14, 2021
Abate by
Nov 1, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:   (a) Elward Systems Corporation at 680 Harlan St. Lakewood, CO 80214: On or before 7/28/21 the employer did not protect employees from injury in that the guard assembly including non-kickback fingers or dogs were not installed on the Rockwell Unisaw tablesaw [model: 5-66, serial number: KR2018] while in use by employees. This condition exposed employees to amputation hazards.  Abatement Note: Abatement certification is required for this item. See enclosed "Certification of Corrective Actions Worksheet."
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Elward Systems Corporation's full OSHA safety record →