Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SKY FRAMING, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SKY FRAMING, LLC. in 122 NEW YORK AVENUE, JERSEY CITY, NJ 07307 (NAICS 238130). OSHA activity number 345446991.

Watch SKY Framing, LLC. — free Get an email when a new federal OSHA severe-injury report for SKY Framing, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
SKY FRAMING, LLC.
Site address
122 NEW YORK AVENUE
City
JERSEY CITY
State
NJ
ZIP
07307
Mailing
275 WASHINGTON AVENUE, NUTLEY, NJ 07110
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 III C

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3511.00 · Current $0.00 Reduced
29 CFR  1926.404(b)(1)(iii)(C):The employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage:  a) Worksite was located at 122 New York Avenue; Jersey City, NJ 07307  A subcontractor's employees were exposed to electrical hazards as they were working with defective power cords to power a temporary lighting string on the ground floor of the building.  Violation was observed on or about July 23, 2021.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3511

1926.405 A02 II E

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3511.00 · Current $0.00 Reduced
29 CFR  1926.405(a)(2)(ii)(E):Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:  a) Worksite was located at 122 New York Avenue; Jersey City, NJ 07307  A subcontractor's employees were exposed to electrical hazards as they were working with  a temporary lighting string on the ground floor of the building that did not have cages on the bulbs to protect them from incidental contact and breakage.  Violation was observed on or about July 23, 2021.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3511

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1926.451(f)(6):Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section:  a) Worksite was located at 122 New York Avenue; Jersey City, NJ 07307  A subcontractor's employee was exposed to electrical hazards as he was working from a JLG Lift bringing materials up to the upper floors of the building under construction within 18 inches of 13kV power lines.  Violation was observed on or about July 21, 2021.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) Worksite was located at 122 New York Avenue, Jersey City, NJ 07307  A subcontractor's employees were exposed to fall hazards of greater than thirty feet as they were hanging out of the fourth story windows while installing window frames with no fall protection or fall arrest system in place to prevent them from falling to concrete and debris on the ground below.  Violation was observed on or about July 23, 2021
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

View SKY FRAMING, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345446991.