HOUSTON, TX —
OSHA Inspection: MCDANIEL METALS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCDANIEL METALS, LLC in 1318 BUSCHONG ST., HOUSTON, TX 77039 (NAICS 332322). OSHA activity number 345449276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCDANIEL METALS, LLC
- Site address
- 1318 BUSCHONG ST.
- City
- HOUSTON
- State
- TX
- ZIP
- 77039
- Mailing
- 1318 BUSCHONG ST., HOUSTON, TX 77039
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 130
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.101 B
- Issued
- Dec 13, 2021
- Abate by
- Jan 6, 2022
- Penalty
- Initial $8,778 · Current $4,389 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about July 29, 2021 at the sheet metal shop where cylinders were not secured in accordance to Compressed Gas Association Pamphlet P-1-1965.
Recent events (2)
- — I (S) $4389
- — Z (S) $8778
1910.134 E01
- Issued
- Dec 13, 2021
- Penalty
- Initial $7,022 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about July 29, 2021 employees did not receive initial medical evaluation for the half face respirators they were using.
Recent events (2)
- — I (S) $3511
- — Z (S) $7022
1910.134 F01
- Issued
- Dec 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1):The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): On or about July 29, 2021 employees were not fit tested for the half face respirators they were using.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Dec 13, 2021
- Penalty
- Initial $8,778 · Current $4,389 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about July 15, 2021, an employee was exposed to an amputation hazard using a band saw without the unused portion of the blade and the head assembly of the machine being guarded.
Recent events (2)
- — I (S) $4389
- — Z (S) $8778
1910.212 A03 II
- Issued
- Dec 13, 2021
- Abate by
- Jan 7, 2022
- Penalty
- Initial $8,778 · Current $4,389 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about July 29, 2021 an employee was exposed to a crushed-by hazard as he was working on the 109 press brake that was not guarded.
Recent events (2)
- — I (S) $4389
- — Z (S) $8778
1910.252 B02 III
- Issued
- Dec 13, 2021
- Penalty
- Initial $7,022 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used: On or about July 29, 2021 at the sheet metal shop where welding was done and welding screens were not being used.
Recent events (2)
- — I (S) $3511
- — Z (S) $7022
1910.304 F01 IV
- Issued
- Dec 13, 2021
- Penalty
- Initial $8,778 · Current $4,389 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: On or about July 29, 2021 at the shipping and receiving area of the facility where there were pallets of boxes blocking electrical breaker panels.
Recent events (2)
- — I (S) $4389
- — Z (S) $8778
1910.303 F02
- Issued
- Dec 13, 2021
- Abate by
- Dec 28, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about July 29, 2021 employees were exposed to electrical hazards at the sheet metal shop where two breaker boxes were not labeled to identify each breaker and or switch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Dec 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:(a) On or about July 29, 2021 employees were exposed to electrical hazards as there were two electrical breaker boxes that had unused openings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Dec 13, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about July 29, 2021 near the coil line Pin spotter machine there was a fire extinguisher that was blocked by stacked metal components.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mcdaniel Metals, LLC
View Mcdaniel Metals, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345449276.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.