OSHA Inspection: SMITH TANK - STEEL INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMITH TANK - STEEL INC in 42422 HWY 30, GONZALES, LA 70737 (NAICS 238120). OSHA activity number 345450423.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Smith Tank - Steel INC — free Get an email when a new federal OSHA severe-injury report for Smith Tank - Steel INC is published. One employer, no account, unsubscribe in one click.
Site address
42422 HWY 30
City
GONZALES
State
LA
ZIP
70737
Mailing
42422 HWY 30, GONZALES, LA 70737
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
70
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2021
Abate by
Oct 4, 2021
Penalty
Initial $12,288 · Current $12,288
29 CFR  1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips, and sparks.  On or about July 30, 2021, on the south side of the main fabrication bay; employees utilized a HEM Saw (S.N. # 1189314) to cut metal during machine operations that were not equipped with a guard.
Recent events (2)
  • — I (O) $12288
  • — Z (S) $12288

1910.305 G02 III

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Sep 15, 2021
Penalty
Initial $5,266 · Current $5,266
29 CFR  1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  On or about July 30, 2021 employees utilized an extension cord with strain relief damage to power a DeWalt grinder.
Recent events (2)
  • — I (O) $5266
  • — Z (S) $5266

1910.334 A02 I

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Sep 15, 2021
Penalty
Initial $5,266 · Current $5,266
29 CFR  1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to an outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).   On or about July 30, 2021, employees engaged in machining operations were exposed to electrical shock hazards due to the employer failing to visually inspect the flexible cord used to power hand tools.
Recent events (2)
  • — I (O) $5266
  • — Z (S) $5266

1910.334 A03 I

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Sep 15, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(3)(i): A flexible cord used with grounding type equipment shall contain an equipment grounding conductor.   On or about July 30, 2021,  on the south side of the fabrication shop rear area, a forty-two (42) inch orange shop fan was being used with a damaged power cord and missing ground prong by an employee doing machining work.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 3 exposed
Issued
Sep 15, 2021
Abate by
Sep 30, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located, and identified so that they were readily accessible without subjecting the employees to injuries.   On or about July 30, 2021, on the east side of the shop twenty-six feet from bay door number four, a fire extinguisher was blocked.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0