OSHA Inspection: G I ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G I ROOFING, LLC in 2734 SPRINGDALE RD., CINCINNATI, OH 45251 (NAICS 238160). OSHA activity number 345451249.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G I Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for G I Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
G I ROOFING, LLC
Site address
2734 SPRINGDALE RD.
City
CINCINNATI
State
OH
ZIP
45251
Mailing
4248 GLENDALE MILFORD RD., CINCINNATI, OH 45242
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 2, 2021
Penalty
Initial $3,686 · Current $3,000 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  (a) On July 30, 2021, located on the north side of a residential low pitch roof, an employee was exposed to a fall hazard removing shingles while not utilizing any fall protection system. Potential fall height measured to be greater than 6 feet. Roof pitch measured to be 4 in 12.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $3686

1926.502 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 2, 2021
Penalty
Initial $3,686 · Current $0 Reduced
29 CFR 1926.502(a)(2): Employers shall provide and install all fall protection systems required by this subpart for an employee, and shall comply with all other pertinent requirements of this subpart before that employee begins the work that necessitates the fall protection. (A)  Guardrail systems;  (B)  Safety net systems; or  (C)  Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.  (a) On July 30, 2021, located on the north side of a residential low pitch roof, the employer failed to install a fall protection system prior to an employee removing shingles. Potential fall height measured to be greater than 6 feet. Roof pitch measured to be 4 in 12.