Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTION JACKSON AUTO LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACTION JACKSON AUTO LLC in 41000 HIGHWAY 6, AVON, CO 81620 (NAICS 811111). OSHA activity number 345452684.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Action Jackson Auto LLC — free Get an email when a new federal OSHA severe-injury report for Action Jackson Auto LLC is published. One employer, no account, unsubscribe in one click.
Site address
41000 HIGHWAY 6
City
AVON
State
CO
ZIP
81620
Mailing
41000 HIGHWAY 6, AVON, CO 81620
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
13
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 13 exposed
Issued
Jan 14, 2022
Abate by
Feb 10, 2022
Penalty
Initial $5,461 · Current $1,500 Reduced
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards while operating automotive lifts:  (a) ACTIONA JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the employer did not ensure that employees were safe from crushing and struck-by hazards in that 6 automotive lifts, including (2) Rotary 2 Post Surface Mounted automobile lifts, model numbers: SP010N700 and SP0A9-202,  were not inspected periodically by a qualified inspector at least annually to ensure that they were properly used, maintained and functioning. This condition exposed employees to struck-by and crushed-by hazards.   Abatement Note: Among other methods, feasible and acceptable methods of abatement would be to follow the requirements of ANSI/ALI ALOIM - Standard for Automotive Lifts - Safety Requirements for operation, Inspection and Maintenance, which includes, among other requirements, the following: Ensure that all automotive lifts are inspected by a qualified lift inspector at least annually.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $5461

1910.1200 E01

Serious Gravity 5 1 instance 13 exposed
Issued
Jan 14, 2022
Abate by
Feb 10, 2022
Penalty
Initial $4,681 · Current $1,500 Reduced
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) ACTION JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the employer did not develop and implement a written hazard communication program that pertains to employee use of chemicals such as, but not limited to the following: Autozone R-134a Refrigerant, CRC Battery Cleaner,  Xtra Seal Vulcanizing Cement, and Zenith Windshield Washer. This condition exposed employees to skin irritation and injury, lung irritation and injury, and eye irritation and injury.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4681

1910.1200 G01

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 14, 2022
Abate by
Feb 10, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(1):The employer did not have a safety data sheet in the workplace for each hazardous chemical which they use.  (a) ACTION JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the employer did not provide employees with access to Safety Data Sheets for chemicals in workplace, including, but not limited to following chemicals: Autozone R-134a Refrigerant, CRC Battery Cleaner,  Xtra Seal Vulcanizing Cement, and Zenith Windshield Washer. This condition exposed employees to skin irritation and injury, lung irritation and injury, and eye irritation and injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 15 exposed
Issued
Jan 14, 2022
Abate by
Feb 10, 2022
Penalty
Initial $4,681 · Current $1,500 Reduced
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) ACTION JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area, such as but not limited to the following chemicals: Autozone R-134a Refrigerant, CRC Battery Cleaner,  Xtra Seal Vulcanizing Cement, and Zenith Windshield Washer. This condition exposed employees to skin irritation and injury, lung irritation and injury, and eye irritation and injury.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4681

1910.305 G01 IV A

Serious Gravity 1 1 instance 15 exposed
Issued
Jan 14, 2022
Abate by
Jan 31, 2022
Penalty
Initial $2,340 · Current $1,500 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) ACTION JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the employer used flexible cords and/or cables as a substitute for the fixed wiring of a structure.  The employer used a temporary power tap and extensions cords in the garage of the facility to power compressors and charge power tools. A total of 4 separate cords were used  This condition exposed the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2340

1910.305 B02 I

Serious Gravity 1 1 instance 15 exposed
Issued
Jan 14, 2022
Abate by
Jan 27, 2022
Penalty
Initial $2,340 · Current $1,500 Reduced
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) ACTION JACKSON AUTO LLC at 41000 Highway 6, Avon, CO 81620: On or before August 2, 2021, the electrical outlet junction box located on the east wall of the first garage bay did not have the correct cover installed, thus potentially exposing employees to energized parts. This condition exposed the employees to the hazard of electrical shock.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2340

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345452684.