CHICAGO, IL —
OSHA Inspection: SOUTHWEST INDUSTRIES, INC. DBA ANDERSON ELEVATOR CO.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SOUTHWEST INDUSTRIES, INC. DBA ANDERSON ELEVATOR CO. in 1969 W. OGDEN AVE., CHICAGO, IL 60612 (NAICS 238290). OSHA activity number 345454219.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHWEST INDUSTRIES, INC. DBA ANDERSON ELEVATOR CO.
- Site address
- 1969 W. OGDEN AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60612
- Mailing
- 2801 S. 19TH AVE., BROADVIEW, IL 60155
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 103
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.28 B02 I
- Issued
- Jan 24, 2022
- Penalty
- Initial $14,502 · Current $13,050 Reduced
General-duty citation text
29 CFR 1910.28(b)(2)(i): The employer did not ensure that each employee in a hoist area is protected from falling 4 feet (1.2 m) or more to a lower level by one of the systems listed in 29 CFR 1910.28(b)(2)(i)(A)-(C). a. On or about July 31, 2021, at the above addressed facility, an employee, performing maintenance operations on staff elevators #19 and #20, entered the hoistway area and was not protected from falling approximately sixteen (16) feet to the lower level, thereby exposing the employee to fall hazards.
Recent events (2)
- — I (S) $13050
- — Z (S) $14502
1910.28 B06 I
- Issued
- Jan 24, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(6)(i): The employer did not ensure that each employee less than 4 feet (1.2 m) above dangerous equipment is protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard. a. On or about July 31, 2021, at the above addressed facility, an employee was required to access the elevator shaft to conduct maintenance activities on elevator banks #19 & #20. The employee was exposed to struck by hazards and fall hazards when the elevator doors were open for the employee to gain access to the top of the elevators.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jan 24, 2022
- Penalty
- Initial $13,052 · Current $13,050 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about July 31, 2021, at the above addressed facility, the employer had a written energy control program, but did not conduct an annual periodic inspection of the program, thereby exposing an employee to struck-by hazards and fall hazards when performing maintenance operations.
Recent events (2)
- — I (S) $13050
- — Z (S) $13052
1910.147 D
- Issued
- Jan 24, 2022
- Penalty
- Initial $14,502 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):(a) a) On or about July 31, 2021, an employee was exposed to machine hazards associated with moving parts when elevator #19 and #20 were not locked out, which resulted in a fatality. The employer failed to implement energy control application steps as the elevators were not shut down or turn off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $14502
More inspections at Southwest Industries, INC. DBA Anderson Elevator CO.
View Southwest Industries, INC. DBA Anderson Elevator CO.'s full OSHA safety record →
More inspections in this industry (NAICS 238290)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345454219.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.