Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M ABRAHAM FLOORS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of M ABRAHAM FLOORS in 1001 ROUTE 315, PLAINS TOWNSHIP, PA 18702 (NAICS 238330). OSHA activity number 345459903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M Abraham Floors — free Get an email when a new federal OSHA severe-injury report for M Abraham Floors is published. One employer, no account, unsubscribe in one click.
Establishment
M ABRAHAM FLOORS
Site address
1001 ROUTE 315
City
PLAINS TOWNSHIP
State
PA
ZIP
18702
Mailing
112 BROWN ROAD, PITTSTON, PA 18640
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238330
Employees
1
Ownership type
A

3 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Jan 11, 2022
Abate by
Feb 14, 2022
Penalty
Initial $652 · Current $0 Reduced
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) Location -  Room 204  On or about August 5, 2021 the employer did not provide the abatement certification to OSHA within 10 calendar days after the abatement date.
Recent events (2)
  • — I (O) $0
  • — Z (O) $652

1926.404 B01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 4, 2021
Penalty
Initial $3,481 · Current $2,500 Reduced
29 CFR  1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  (a) Room 204 - An employee was exposed to a shock hazard in that an air compressor was plugged into an outlet that was not installed with a ground fault circuit interrupter (GCFI), on or about August 5, 2021.  Certification not required.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3481

1926.405 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 4, 2021
Abate by
Nov 10, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  (a) Room 204 - An employee was exposed to a shock hazard in that an air compressor was plugged into an outlet with exposed live parts since it did not have a cover, faceplate, or fixture canopy installed, on or about August 5, 2021.  Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View M Abraham Floors's full OSHA safety record →