Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRICO PEANUT, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRICO PEANUT, LLC in 1172 US 385 N, SEMINOLE, TX 79360 (NAICS 424590). OSHA activity number 345460125.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trico Peanut, LLC — free Get an email when a new federal OSHA severe-injury report for Trico Peanut, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
TRICO PEANUT, LLC
Site address
1172 US 385 N
City
SEMINOLE
State
TX
ZIP
79360
Mailing
1172 US 385 N, SEMINOLE, TX 79360
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424590
Employees
23
Ownership type
A

2 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 10, 2021
Abate by
Oct 8, 2021
Penalty
Initial $3,901 · Current $2,341 Reduced
29 CFR 1910.95(c)(1):  A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level (TWA) of 85 dBA:  On or about August 04, 2021, and at times prior thereto, at a workplace located at 1172 US Hwy 385 N., Seminole, Texas; employees were exposed to continuous noise level at 130.1% of the allowable 8-hour time-weighted average sound level (85 dBA). The equivalent dBA level of 130.1% is approximately 91.9 dBA. The sampling was performed for 426 minutes during one shift on August 12, 2021. Zero exposure was assumed for the 54 minutes not sampled.
Recent events (2)
  • — I (S) $2340.6
  • — Z (S) $3901

1910.212 A01

Serious Gravity 10 3 instances 3 exposed
Issued
Sep 10, 2021
Abate by
Oct 8, 2021
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR 1910.212(a)(1):  Machine guarding was not provided to protect operator(s) and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:                                                                                                                      On or about August 04, 2021, and at times prior thereto, at a workplace located at 1172 US Hwy 385 N., Seminole, Texas; employees cleaning drum sizer gearheads were exposed to arm and/or hands entering into point of operation of the machine during the operation cycle due to insufficient point of operation guard installed on gearhead of the drum sizer.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345460125.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.