CARENCRO, LA —
OSHA Inspection: DALEY TOWER SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DALEY TOWER SERVICE, INC. in 605 HECTOR CONNOLY RD, CARENCRO, LA 70520 (NAICS 237130). OSHA activity number 345460216.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DALEY TOWER SERVICE, INC.
- Site address
- 605 HECTOR CONNOLY RD
- City
- CARENCRO
- State
- LA
- ZIP
- 70520
- Mailing
- 1223 W. GLORIA SWITH RD., CARENCRO, LA 70520
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237130
- Employees
- 16
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.215 A04
- Issued
- Sep 15, 2021
- Penalty
- Initial $6,827 · Current $4,779 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth (1/8) inch. On or about August 2, 2021, on the east side, fabrication shop employee(s) utilized a Central Machinery eight-inch (8) bench grinder (no serial number) to clean and smooth rough areas in the machining process with an opening between the work rest and grinding wheel greater than a one-eighth inch.
Recent events (2)
- — I (S) $4778.9
- — Z (S) $6827
1910.243 C03
- Issued
- Sep 15, 2021
- Penalty
- Initial $9,557 · Current $6,690 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on the vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel. On or about August 2, 2021, on the east side fabrication shop area, an employee was using a DeWalt 4 1/2 inch angle grinder without an adequate guard while performing fabrication tasks.
Recent events (2)
- — I (S) $6689.9
- — Z (S) $9557
1910.305 B02 I
- Issued
- Sep 15, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $5,461 · Current $3,823 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about August 2, 2021, on the east side fabrication shop, employees worked near a junction box that was open with exposed wiring and connectors that had live electrical current.
Recent events (2)
- — I (S) $3822.7
- — Z (S) $5461
1910.157 C01
- Issued
- Sep 15, 2021
- Abate by
- Sep 30, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located, and identified so that they were readily accessible without subjecting the employees to injuries. On or about August 2, 2021, Southeast side fabrication shop a fire extinguisher was blocked by material, making it inaccessible to workers performing machining operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Daley Tower Service, INC.
View Daley Tower Service, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237130)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345460216.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.