VIERA, FL —
OSHA Inspection: TIDAL WAVE ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIDAL WAVE ROOFING, INC. in 8301 PARAGRASS AVENUE, VIERA, FL 32940 (NAICS 238160). OSHA activity number 345461552.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIDAL WAVE ROOFING, INC.
- Site address
- 8301 PARAGRASS AVENUE
- City
- VIERA
- State
- FL
- ZIP
- 32940
- Mailing
- PO BOX 237843, COCOA, FL 32923
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 30, 2021
- Penalty
- Initial $3,121 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about 07/27/2021, at a new residential property located at 8301 Paragrass Ave. Viera, FL, employees were not wearing fall protection while installing flashing material on a residential roof with a slope of 6:12, exposing employees to a fall hazard of approximately 12 feet to ground level
Recent events (2)
- — I (S) $0
- — Z (S) $3121
1926.1053 B06
- Issued
- Nov 30, 2021
- Penalty
- Initial $3,121 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a. On or about 07/27/2021, at a new residential property located at 8301 Paragrass Ave. Viera, FL, two employees were exposed to a fall hazard of approximately 12 feet to ground level, in that; a ladder that was not secured to prevent from being displaced, sunk approximately 1-foot into the soil, where it was being used to access a roof.
Recent events (2)
- — I (S) $0
- — Z (S) $3121
More inspections at Tidal Wave Roofing, INC.