SEATTLE, WA —
OSHA Inspection: NOAA PACIFIC MARINE ENVIRONMENTAL LABORATORY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NOAA PACIFIC MARINE ENVIRONMENTAL LABORATORY in 7600 SAND POINT WAY NE BUILDING 3, 8 AND 32, SEATTLE, WA 98115 (NAICS 541715). OSHA activity number 345464739.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOAA PACIFIC MARINE ENVIRONMENTAL LABORATORY
- Site address
- 7600 SAND POINT WAY NE BUILDING 3, 8 AND 32
- City
- SEATTLE
- State
- WA
- ZIP
- 98115
- Mailing
- 7600 SAND POINT WAY NE, SEATTLE, WA 98115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541715
- Employees
- 173
- Ownership type
- D
Citations
8 citations on file for this inspection.
1910.101 B
- Issued
- Sep 2, 2021
- Abate by
- Sep 10, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (a) Building 3 Room 1082- Buoy Systems Lab; A Black compressed gas cylinder containing air was not secured. This exposes employees to potential struck by hazards.
Recent events (1)
- — Z (S) $0
1910.133 A01
- Issued
- Sep 2, 2021
- Abate by
- Sep 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1):The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) Building 8 Acoustic Release Laboratory; Chemical splash goggles were not provided to an employee who uses a corrosive acid bath (5% Oakite 31, which is diluted to 2-3% phosphoric acid) to clean tools and make new baths from the concentrated chemical two times a year.
Recent events (1)
- — Z (S) $0
1910.141 G02
- Issued
- Sep 2, 2021
- Abate by
- Sep 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials: (a) Building 3, Room 1105; The middle soldering station (where employees use lead containing solder) had an empty water bottle, candy and gum located in the work area. This exposes employees to possible lead ingestion hazards.
Recent events (1)
- — Z (S) $0
1910.145 C02 I
- Issued
- Sep 2, 2021
- Abate by
- Sep 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices: (a) Building 3 Room 1105; The soldering station in the middle of the room did not have CAUTION LEAD signage. (b) Building 8 PMEL Carbon Group; The soldering station did not have CAUTION LEAD signage. Caution signs were not posted to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder. This exposes employees to potential lead ingestion hazards.
Recent events (1)
- — Z (S) $0
1910.1025 H01
- Issued
- Sep 2, 2021
- Abate by
- Sep 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead: (a) Building 3 Room 1105; The soldering station in the middle of the room had surface lead contamination. (b) Building 3 Room 1105: The soldering station located in the West end of the room had surface lead contamination. (c) Building 8, PMEL Carbon Group; The soldering station had surface lead contamination. This exposes employees to lead ingestion hazards. *Please note that surfaces (other than glass or metal) are porous and gritty scrubbing cleaners (examples are Soft Scrub, Comet or Ajax) are sometimes needed to fully decontaminate the area from surface lead contamination. Lead wipes are also effective.
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Sep 2, 2021
- Abate by
- Sep 22, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Building 8, PMEL Carbon Group. A metal handy box with holes, designed to be permanently installed in a wall, was used for portable electrical power. The metal handy box was attached to a cord and hung from center of the room's ceiling to power equipment which measures CO2 in ocean water. This exposes employees to possible electrical shock hazards.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Sep 2, 2021
- Abate by
- Oct 8, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Building 8 PMEL Carbon Group; A Mr. Coffee coffee pot, Emerson microwave, and GE refrigerator were plugged into an extension cord for longer than 90 days due to lack of wall outlets.
Recent events (1)
- — Z (O) $0
1910.1200 F06 II
- Issued
- Sep 2, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) Building 3 Room 1107; An Orange spool of solder was not labeled, and it contained lead as indicated by lead checks. This exposes employees to lead ingestion hazards. b) Building 3 Room 1107; A white laboratory squirt bottle containing isopropyl alcohol was not labeled. This exposes employees to respiratory irritation and/or dermatitis hazards.
Recent events (1)
- — Z (O) $0
More inspections at Noaa Pacific Marine Environmental Laboratory
View Noaa Pacific Marine Environmental Laboratory's full OSHA safety record →
More inspections in this industry (NAICS 541715)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345464739.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.