HENNING, IL —
OSHA Inspection: FULL-FILL INDUSTRIES, L.L.C.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FULL-FILL INDUSTRIES, L.L.C. in 400 MAIN STREET, HENNING, IL 61848 (NAICS 424490). OSHA activity number 345467146.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FULL-FILL INDUSTRIES, L.L.C.
- Site address
- 400 MAIN STREET
- City
- HENNING
- State
- IL
- ZIP
- 61848
- Mailing
- PO BOX 158, HENNING, IL 61848
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424490
- Employees
- 150
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Nov 24, 2021
- Abate by
- Dec 17, 2021
- Penalty
- Initial $9,655 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: On or about August 10, 2021, employees were exposed to injuries when performing maintenance and servicing on equipment, including but not limited to, Line 4 and 6 Box Former, because the employer did not conduct an annual inspection of the machine specific procedures, to ensure the procedures and requirements of this standard were followed.
Recent events (3)
- — F (S) $8000
- — C (S) $9655
- — Z (S) $9655
1910.147 C06 II
- Issued
- Nov 24, 2021
- Abate by
- Dec 17, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about August 10, 2021, employees were exposed to injuries when performing maintenance and servicing on equipment, including but not limited to, the Line 4 and Line 6 Box Former, and the employer did not certify periodic inspection had been performed. The certification shall include identification of the machine or equipment, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Nov 24, 2021
- Abate by
- Dec 17, 2021
- Penalty
- Initial $9,655 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about August 10, 2021, Employees were exposed to hazardous energy sources when performing maintenance and servicing, including but not limited on the Line 4 and 6 Box Former , because the employee did not effectively isolating all energy sources and the employer did not did not cover the action listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). Employees who performed servicing and maintenance were not required to: (1) Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) Turn off and shut down the machine, (3) Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) Affix lockout or tagout devices to each energy isolating device, (5) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished. (6) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished.
Recent events (3)
- — F (S) $0
- — C (S) $9655
- — Z (S) $9655
1910.147 C07 III C
- Issued
- Nov 24, 2021
- Abate by
- Dec 17, 2021
- Penalty
- Initial $19,311 · Current $8,000 Reduced
General-duty citation text
1910.147(c)(7)(iii)(C) The retraining did not reestablish employee proficiency and introduce new or revised control methods and procedures, as necessary. On or about August 11, 2021, affected employees on the Line 4 and 6 Box Former did not receive retraining sufficient to establish proficiency in jam clearing procedure after employer had reason to believe that there were deviations from proper use of the jam clearing procedures.
Recent events (3)
- — F (S) $8000
- — C (R) $19311
- — Z (R) $19311
More inspections at Full-Fill Industries, L.L.C.
View Full-Fill Industries, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 424490)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345467146.