SHIREMANSTOWN, PA —
OSHA Inspection: SECCO INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SECCO INC. in 506 SAINT JOHNS ROAD, SHIREMANSTOWN, PA 17011 (NAICS 237110). OSHA activity number 345468060.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SECCO INC.
- Site address
- 506 SAINT JOHNS ROAD
- City
- SHIREMANSTOWN
- State
- PA
- ZIP
- 17011
- Mailing
- 1111 PRIMROSE AVE, CAMP HILL, PA 17011
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.651 J02
- Issued
- Sep 29, 2021
- Abate by
- Oct 26, 2021
- Penalty
- Initial $6,144 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: (a) Excavation in Front Yard and Parallel to St. Johns Road - An employee worked in the excavation, dug in Type B soil, to install a sewer line cleanout pipe near the road. The employer did not keep the pile of soil dug from the excavation and placed along the western wall at least two feet from the edge of the excavation nor use retaining devices to keep the material from falling into the excavation and striking the employee working in the excavation, on or about August 3, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $6144
1926.651 K01
- Issued
- Sep 29, 2021
- Abate by
- Oct 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a) Excavation in Front Yard and Parallel to St. Johns Road - The employer did not have a competent person on the job site in that none of the employees who worked on the site on August 3, 2021 inspected the job site, identified predictable trenching and excavation hazards, and took immediate actions to correct the hazards. As a result, an employee worked in an unprotected trench, dug in Type B soil at best, ranging from 5 feet 10 inches to 6 feet deep, to install a sewer line cleanout pipe near the road. In addition, this 10-foot long by 3-foot 8-inch wide trench did not have the excavated soil pile at least 2 feet back from the edge along the western wall and had a 6-foot step ladder, used in the folded position and not extending 3 feet above the trench's top surface, for access, exposing employees to cave-in, struck-by, and fall hazards. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Sep 29, 2021
- Abate by
- Oct 26, 2021
- Penalty
- Initial $6,144 · Current $11,200
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): (a) Excavation in Front Yard and Parallel to St. Johns Road - An employee worked in a trench, dug in Type B soil at best, to install a cleanout pipe near the road. This 10-foot long by 3-foot 8-inch wide trench ranged from 5 feet 10 inches to 6 feet deep and had unprotected vertical side walls, exposing the employee to a cave-in hazard, on or about August 3, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $11200
- — Z (S) $6144
1926.1053 B01
- Issued
- Sep 29, 2021
- Abate by
- Oct 26, 2021
- Penalty
- Initial $3,686 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Excavation in Front Yard and Parallel to St. Johns Road - An employee used a folded 6-foot Werner step ladder for access to a trench ranging from 5 feet 10 inches to 6 feet deep. The ladder did not extend 3 feet above the trench's top surface, exposing the employee to a fall hazard, on or about August 3, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $3686
1926.1053 B04
- Issued
- Sep 29, 2021
- Abate by
- Oct 26, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed: (a) Excavation in Front Yard and Parallel to St. Johns Road - An employee used a 6-foot Werner step ladder, in the folded rather than open position (for which it was designed), for access to a trench ranging from 5 feet 10 inches to 6 feet deep, exposing the employee to a fall hazard, on or about August 3, 2021. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Secco INC.
View Secco INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345468060.