Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTHERN TOOL DISTRIBUTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORTHERN TOOL DISTRIBUTION in 4600 WATSON RD., ARLINGTON, TX 76010 (NAICS 444210). OSHA activity number 345469738.

Watch Northern Tool Distribution — free Get an email when a new federal OSHA severe-injury report for Northern Tool Distribution is published. One employer, no account, unsubscribe in one click.
Site address
4600 WATSON RD.
City
ARLINGTON
State
TX
ZIP
76010
Mailing
4600 WATSON RD., ARLINGTON, TX 76010
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444210
Employees
150
Ownership type
A

3 citations on file for this inspection.

1910.178 M05 II

Serious Gravity 10 7 instances 4 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $8192.00 Reduced
29 CFR  1910.178(m)(5)(ii):A powered industrial truck is unattended when the operator is 25 ft. or more away from the vehicle which remains in his view, or whenever the operator leaves the vehicle and it is not in his view.  On or about August 11, 2021 and times prior thereto , the employer did not ensure powered industrial trucks were not being left unattended and powered ON by either distance or operator field of view in the following instances:  a) PIT out of the field of view of operator near the IC Department Desk b) PIT unattended by distance near Dock 127 c) PIT unattended by distance near Dock 22 d) PIT unattended by distance near Aisle 603 e) PIT unattended by field of view of operator near Replenishment Department Desk f)  PIT unattended by field of view of operator near Dock 150 g) PIT unattended by distance near Aisle 508
Recent events (2)
  • — I (S) $8191.8
  • — Z (S) $13653

1910.157 C01

Other-than-serious 4 instances 150 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  On or about August 11, 2021 and times prior there to, the employer did not ensure that portable fire extinguisher locations were clearly and visibly identified in order to be readily accessible during an emergency in the following instances:  a) Warehouse entry door adjacent to the Human Resources Office, 1st floor.  b) Designated Emergency Exit Door located adjacent to Dock 124. c) Designated Emergency Exit Door located adjacent to Dock 120. d) Located on the left and right sides of the bay door to the Battery Charging/Floor Scrubber Storage Room
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(D): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where attached to building surfaces.  On or about August 11, 2021 and times prior there to, the employer did not ensure that relocatable power taps were not secured to the permanent structure of the building.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0