ROUND LAKE, IL —
OSHA Inspection: BAXTER HEALTHCARE CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BAXTER HEALTHCARE CORPORATION in 25212 W. IL ROUTE 120, ROUND LAKE, IL 60073 (NAICS 325412). OSHA activity number 345476436.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAXTER HEALTHCARE CORPORATION
- Site address
- 25212 W. IL ROUTE 120
- City
- ROUND LAKE
- State
- IL
- ZIP
- 60073
- Mailing
- 25212 W. IL ROUTE 120, ROUND LAKE, IL 60073
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 30
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Jan 28, 2022
- Penalty
- Initial $10,360 · Current $10,360
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6): 1. Turn off and shut down power to the machinery, 2. Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s), 3. Affix lockout/tagout devices to each energy isolating device, 4. Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work: a) Galaxy Department- On or about August 4 2021, employees were exposed to machine hazards associated with moving parts while performing maintenance and servicing tasks on the Galaxy Machines, such as clearing film jams and changing knife blades. The employer did not implement energy control application steps as the machine was not shut down or turned off to perform servicing work or adjustments [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. No abatement certification or abatement required for this item.
Recent events (1)
- — Z (S) $10360
More inspections at Baxter Healthcare Corporation
View Baxter Healthcare Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345476436.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.