1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SERTA SIMMONS BEDDING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SERTA SIMMONS BEDDING, LLC in 17850 E 32ND PLACE, AURORA, CO 80011 (NAICS 337910). OSHA activity number 345480156.

Watch Serta Simmons Bedding, LLC — free Get an email when a new federal OSHA severe-injury report for Serta Simmons Bedding, LLC is published. One employer, no account, unsubscribe in one click.
Site address
17850 E 32ND PLACE
City
AURORA
State
CO
ZIP
80011
Mailing
17850 E 32ND PLACE, AURORA, CO 80011
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337910
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.101 B

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7748.00 · Current $0.00 Reduced
29 CFR  1910.101(b):The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) Serta Simmons Bedding, LLC at 17850 E 32nd Place in Aurora, Colorado: On or before August 18, 2021, the employer did not ensure that a compressed gas cylinder of argon/carbon dioxide was stored with a valve protection cap in place. This condition exposed employees to a projectile hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7748

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  (a) Serta Simmons Bedding, LLC at 17850 E 32nd Place in Aurora, Colorado: On or before August 18, 2021, the employer did not ensure that compressed gas cylinders of oxygen and acetylene were stored separately at a minimum distance of 20 feet apart. This condition exposed employees to a fire and explosion hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $9687.00 · Current $5000.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Serta Simmons Bedding, LLC at 17850 E 32nd Place in Aurora, Colorado: On or before August 18, 2021, the employer did not ensure employees were protected from pinch points on the C3 line at the mattress flipping station. This condition exposed employees to crushing and amputation hazards.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9687

1910.212 A03 II

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) Serta Simmons Bedding, LLC at 17850 E 32nd Place in Aurora, Colorado: On or before August 18, 2021, the employer did not ensure employees were protected from pinch points created by the point of operation on the AAC Bagger, which packaged mattresses in plastic sheets. This condition exposed employees to crushing and amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Repeat Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $48433.00 · Current $45000.00 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Serta Simmons Bedding, LLC at 17850 E 32nd Place in Aurora, Colorado: On or before August 18, 2021, the employer did not perform periodic inspections of energy control procedures at least annually to ensure that the procedure and the requirements of this standard were being followed. Maintenance employees regularly performed servicing and maintenance on equipment that required the use of lockout/tagout. This condition exposed employees to amputation hazards and hazardous energy.  Serta Simmons Bedding, LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1171238, Citation 1 Item 1, and was affirmed as a final order on March 8, 2017, with respect to a workplace located at 601 Gateway Blvd, Monroe, OH 45050.
Recent events (2)
  • — I (R) $45000
  • — Z (R) $48433

View SERTA SIMMONS BEDDING, LLC's full OSHA safety record →