Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ABT ELECTRONICS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ABT ELECTRONICS, INC. in 141 BENTON LN., BLOOMINGDALE, IL 60108 (NAICS 811412). OSHA activity number 345482053.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ABT Electronics, INC. — free Get an email when a new federal OSHA severe-injury report for ABT Electronics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
141 BENTON LN.
City
BLOOMINGDALE
State
IL
ZIP
60108
Mailing
1200 N. MILWAUKEE AVE., GLENVIEW, IL 60025
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811412
Employees
1600
Ownership type
A

3 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 2 instances 380 exposed
Issued
Jan 25, 2022
Abate by
May 16, 2022
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.332(b)(1): Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments.  (a) Clients' homes, hard-wired appliances: on or about August 16, 2021, installers and service technicians were exposed to electric shock hazard from unexpected energization during work on or near exposed de-energized parts normally operating above 50 volts. Employees were not trained in and familiar with safety-related work practices related to compliant lockout de-energization sequence. Lockout devices (e.g. circuit breaker locks) were not provided and applied on energy isolating devices (e.g. circuit breakers) prior to starting work.  (b) Clients' homes, hard-wired appliances: on or about August 16, 2021, installers and service technicians were exposed to electric shock hazard during voltage testing on or near energized electrical components above 50 volts. Employees were not trained in and familiar with safety-related work practices related to use of electrical protective equipment such as the voltage-rated rubber insulating gloves with leather protectors.  Abatement documentation is required for these items in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $14502
  • — Z (S) $14502

1910.333 A

Serious Gravity 10 2 instances 380 exposed
Issued
Jan 25, 2022
Abate by
May 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.333(a): Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards.  (a) Clients' homes, hard-wired appliances: on or about August 16, 2021, installers and service technicians were exposed to electric shock hazard from unexpected energization during work on or near exposed de-energized parts normally operating above 50 volts. Lockout devices (e.g. circuit breaker locks) were not provided and applied on energy isolating devices (e.g. circuit breakers) prior to starting work. The requirements for the control of hazardous electric energy were not followed by the employer to maintain written copies of de-energization procedures, and to establish application of energy control sequence for:  - De-energizing equipment per 29 CFR 1910.333(b)(2)(ii)(A) to 29 CFR 1910.333(b)(2)(ii)(D); - Application of locks and tags per 29 CFR 1910.333(b)(2)(iii)(A) to 29 CFR 1910.333(b)(2)(iii)(E); - Verification of de-energized condition per 29 CFR 1910.333(b)(2)(iv)(A) to 29 CFR 1910.333(b)(2)(iv)(B); and, - Re-energizing equipment per 29 CFR 1910.333(b)(2)(v)(A) to 29 CFR 1910.333(b)(2)(v)(D).   (b) Clients' homes, hard-wired appliances: on or about August 16, 2021, installers and service technicians were exposed to electric shock hazard during voltage testing on or near energized electrical components above 50 volts. Safety-related work practices were not implemented to prevent injuries from direct or indirect electrical contacts, such as by wearing electrical protective equipment.  Abatement documentation is required for these items in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 10 1 instance 380 exposed
Issued
Jan 25, 2022
Abate by
May 16, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.   Clients' homes, hard-wired appliances: on or about August 16, 2021, installers and service technicians had their hands exposed to electric shock hazard likely to result in burns during voltage testing on or near energized electrical components operating above 50 volts because voltage-rated rubber insulating gloves with leather protectors were not provided.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).   Abatement Note:  for compliance assistance, refer to OSHA 29 CFR 1910.137 "Electrical Protective Equipment" and NFPA 70E "Standard for Electrical Safety in the Workplace" (2018), www.nfpa.org.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345482053.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.