Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. DEPARTMENT OF INTERIOR, NATIONAL PARK SERVICE in 6565 GREENBELT ROAD, GREENBELT, MD 20770 (NAICS 712190). OSHA activity number 345483689.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Interior, National Park Service — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Interior, National Park Service is published. One employer, no account, unsubscribe in one click.
Site address
6565 GREENBELT ROAD
City
GREENBELT
State
MD
ZIP
20770
Mailing
1100 OHIO DRIVE, SW, WASHINGTON, DC 20242
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
15
Ownership type
D

3 citations on file for this inspection.

1910.213 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 15, 2022
Abate by
Feb 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  a) Carpenter Shop - The Rockwell Delta 10 inch table saw, series number 34-450, serial number FL-580, was not provided with a hood guard when an employee used it to cut two-by pieces of wood stock on or about 08/16/2021.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1910.213 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 15, 2022
Abate by
Feb 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(2):Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  a) Carpenter Shop - The Rockwell Delta 10 inch table saw, series number 34-450, serial number FL-580, was not provided with a  spreader  guard when an employee used it to cut two-by pieces of wood stock on or about 08/16/2021.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1910.213 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 15, 2022
Abate by
Feb 22, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  a) Carpenter Shop -  The Rockwell Delta 10 inch table saw, series number 34-450, serial number FL-580, was not provided with a  non kickback device when an employee used it to cut two-by pieces of wood stock on or about 08/16/2021.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

View U.S. Department of Interior, National Park Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345483689.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.