Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IG DESIGN GROUP AMERICAS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of IG DESIGN GROUP AMERICAS, INC. in 9TH AND BOMBOY LANE, BERWICK, PA 18603 (NAICS 326199). OSHA activity number 345495634.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IG Design Group Americas, INC. — free Get an email when a new federal OSHA severe-injury report for IG Design Group Americas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9TH AND BOMBOY LANE
City
BERWICK
State
PA
ZIP
18603
Mailing
2015 WEST FRONT STREET PO BOX 428, BERWICK, PA 18603
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
200
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 15 exposed
Issued
Nov 4, 2021
Abate by
Jun 30, 2022
Penalty
Initial $11,605 · Current $8,124 Reduced

Hazardous substances E200M110

OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards from combustible particulate solids:  a) Paper scrap and core trimmings baler, the Precision AirConvey enclosureless dust collection system which served machinery which can produce sparks and was not located at least 20 feet (6.1 meters) from any means of egress or area routinely occupied by personnel, was located inside the building, on or about, August 25, 2021.  b) Plastic regrind area, the Donaldson DCE Unimaster dust collection system was not equipped with explosion protection and had a dirty-side volume of approximately 70.5 cubic feet, was located inside the building, on or about, August 25, 2021.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
  • — I (S) $8124
  • — Z (S) $11605

View IG Design Group Americas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345495634.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.