Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S. C. JOHNSON & SON, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of S. C. JOHNSON & SON, INC. in 8311 16TH STREET, STURTEVANT, WI 53177 (NAICS 325612). OSHA activity number 345499990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S. C. Johnson & SON, INC. — free Get an email when a new federal OSHA severe-injury report for S. C. Johnson & SON, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8311 16TH STREET
City
STURTEVANT
State
WI
ZIP
53177
Mailing
8311 16TH STREET, STURTEVANT, WI 53177
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325612
Employees
400
Ownership type
A

1 citation on file for this inspection.

1910.119 D03 I B

Deleted Repeat 1 instance 20 exposed
Issued
Feb 11, 2022
Penalty
Initial $2,070 · Current $0 Reduced
29 CFR  1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process.  (a) On or about September 23, 2021, the inspection of Acetone process piping in Building 51 identified that P&IDs did not reflect current the current equipment and piping configuration on the shell side of heat exchanger HX-0001. The P&IDs did not include the Pressure Relief Device installed on the shell side of HX-0001. The Kunkle Valve was set at 120 psi and a rated capacity of 23 gallons per minute. The P&ID did not show a relief device protecting the shell side of the heat exchanger.   S.C. Johnson & Son, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1449404, citation number 2, item number 2 and was affirmed as a final order on June 22, 2020, with respect to the workplace located at 8311 16th St, Mt Pleasant, WI 53177.
Recent events (2)
  • — I (R) $0
  • — Z (R) $2070

View S. C. Johnson & SON, INC.'s full OSHA safety record →