Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HIGHLITE ELECTRICAL SERVICES LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HIGHLITE ELECTRICAL SERVICES LLC in 41 CENTER AVE, NEW ROCHELLE, NY 10801 (NAICS 238210). OSHA activity number 345500441.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Highlite Electrical Services LLC — free Get an email when a new federal OSHA severe-injury report for Highlite Electrical Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
41 CENTER AVE
City
NEW ROCHELLE
State
NY
ZIP
10801
Mailing
29B SECOR RD., MAHOPAC, NY 10541
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
29
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 6, 2021
Penalty
Initial $3,481 · Current $2,418 Reduced
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  Location: basement On or about: 8/26/21  a) An employee, who was working below overhead hazards such as, but not limited to a falling 4" metal coupler, was not wearing a hard hat.    NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2418
  • — Z (S) $3481

1926.451 F04

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 6, 2021
Penalty
Initial $5,803 · Current $4,062 Reduced
29 CFR  1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired:    location: basement on or about: 8/26/21  a) An employee was working from a defective Skyjack SJIII 3219 scissor lift. The control panel  above the work platform did not allow the operator to raise the lift. A second employee had to raise the platform using a switch at the bottom of the lift. The lift was not immediately repaired, replaced or removed from service until repaired.     NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $4062
  • — Z (S) $5803

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 6, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  location: basement on or about: 8/26/21  a) An employee, engaged in electrical work, was working from a Skylift scissor lift without an adequate guardrail system in place. The midrail at the access area was not engaged. The employee was exposed to a fall of 11 feet 8 inches.    NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345500441.