OSHA Inspection: PLAINVILLE PLATING COMPANY INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PLAINVILLE PLATING COMPANY INC. in 21 FORESTVILLE AVENUE, PLAINVILLE, CT 06062 (NAICS 332813). OSHA activity number 345500573.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Plainville Plating Company INC. — free Get an email when a new federal OSHA severe-injury report for Plainville Plating Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
21 FORESTVILLE AVENUE
City
PLAINVILLE
State
CT
ZIP
06062
Mailing
21 FORESTVILLE AVENUE, PLAINVILLE, CT 06062
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
40
Ownership type
A

7 citations on file for this inspection.

1910.124 J03

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 16, 2022
Abate by
Apr 5, 2022
Penalty
Initial $6,164 · Current $3,082 Reduced
29 CFR  1910.124(j)(3): Periodic inspections of all dipping and coating equipment, including covers, drains, overflow piping, and electrical and fire-extinguishing systems were not conducted, and deficiencies were not promptly corrected:  PRODUCTION AREAS:  On or about September 23, 2021, the employer had not conducted thorough periodic inspections of the dip tanks and equipment taking corrective actions as needed as evidenced by a corroded and broken electrical outlet on Silver Plating Area #6.
Recent events (2)
  • — I (S) $3082
  • — Z (S) $6164

1910.132 D01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 16, 2022
Abate by
Apr 5, 2022
Penalty
Initial $6,164 · Current $3,082 Reduced

Hazardous substances 0689

29 CFR  1910.132(d)(1)(i):The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment:  ANODIZE PLATING LINE:  On or about August 27, 2021, the employer did not select appropriate eye protection when conducting a personal protective equipment (PPE) hazard assessment for the process involving dipping parts into floor-level anodize baths using a hoist-assist.
Recent events (2)
  • — I (S) $3082
  • — Z (S) $6164

1910.133 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 16, 2022
Abate by
Apr 5, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR  1910.133(a)(1):The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  ANODIZE AREA #1:  On or about August 27, 2021, employees dipping parts into floor-level anodize baths using a hoist-assist to move parts in and out of plating tanks wore safety glasses rather than splash goggles.  Some of the tanks contained acidic solutions and most of the tanks were maintained at a temperature between 140 and 212 degrees F.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 3 exposed
Issued
Feb 16, 2022
Penalty
Initial $3,698 · Current $1,849 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On or about August 30, 2021, two relocatable power taps (RPTs) in the Conference Room used to energize multiple desktop computer systems were connected in series.  According to the UL listing for RPTs, the devices are to be directly connected to a permanently installed branch circuit receptacle and are not to be series-connected to other RPTs or connected to extension cords.
Recent events (2)
  • — I (S) $1849
  • — Z (S) $3698

1910.303 B07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 16, 2022
Abate by
Apr 5, 2022
Penalty
Initial $5,803 · Current $2,902 Reduced
29 CFR  1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  SILVER PLATING AREA #6:  On or about September 23, 2021, an electrical outlet located between tanks 14 and 15 was separated from the conduit due to rust and corrosion of the outlet box thereby exposing live wires to potential damage and exposure to plating solutions.  Employees were exposed to potential for electric shock and/or burns.
Recent events (2)
  • — I (S) $2901.5
  • — Z (S) $5803

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 16, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  SILVER PLATING AREA #6:  On or about September 23, 2021, the employer did not ensure that electrical conductors were protected from abrasion or other damage in that a metal electrical outlet intended to be wall-mounted was not properly installed.  The outlet corroded and broke away from the conduit it was attached to exposing electrical conductors that powered the outlet.  The outlet was hanging by the conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 16, 2022
Penalty
Initial $3,698 · Current $1,849 Reduced
29 CFR  1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  RACKING AREA JUST OUTSIDE THE MAIN PLATING AREA:  On or about September 23, 2021, two electrical panels were located with 22 inches of a box dryer.  One panel, PP2, had 240V service.  The other, P2, had 120V service.