Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: I.E. PACIFIC, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of I.E. PACIFIC, INC in MARINE CORP AIR STATION MIRAMAR, SAN DIEGO, CA 92145 (NAICS 236220). OSHA activity number 345516538.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch I.E. Pacific, INC — free Get an email when a new federal OSHA severe-injury report for I.E. Pacific, INC is published. One employer, no account, unsubscribe in one click.
Establishment
I.E. PACIFIC, INC
Site address
MARINE CORP AIR STATION MIRAMAR
City
SAN DIEGO
State
CA
ZIP
92145
Mailing
150 WEST CREST STREET, ESCONDIDO, CA 92025
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.405 G02 IV

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Sep 23, 2021
Penalty
Initial $4,642 · Current $1,857 Reduced
29 CFR  1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  Barracks Bldg. 5697 Exterior Spider Box 125377: Employee(s) used the spider box for temporary power to power tools and equipment. The black 50 Foot 50A 250V single-phase spider box cord end connected to the spider box was found with the strain relief pulled exposing the inner wires. Employees were exposed to electrical shock hazard(s)
Recent events (2)
  • — I (O) $1856.8
  • — Z (S) $4642

1926.416 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 23, 2021
Abate by
Oct 13, 2021
Penalty
Initial $4,642 · Current $1,857 Reduced
29 CFR  1926.416(e)(1): Worn or frayed electric cords or cables were used:  Building 5697, Utility Hallway 3s: Employee(s) used the temporary lighting to conduct work in the utility hallway and/or safe passage. The yellow temporary lighting stringer used to illuminate the utility hallway had cuts in the outer insulation exposing the inner copper wiring on the plug side.  Employee(s) were exposed to electrical shock hazard(s).
Recent events (2)
  • — I (S) $1856.8
  • — Z (S) $4642

1926.501 B04 III

Other-than-serious 4 instances 2 exposed
Issued
Sep 23, 2021
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(4)(iii): Each employee on a walking/working surface was not protected from objects falling through holes (including skylights) by covers:  In the following Locations:  a) Barracks room B256  b) Barracks room B251 c) Barracks room B243 d) Barracks room B235   Employee(s) conducting work on the next lower level were not protected by hole covers for holes grater than 2 inches in the walking working surface which the vertical ducting ran through.  Employee(s) were exposed to tools, materials and/or debris falling through hole(s) to the next lower level 10-12 feet and being struck.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View I.E. Pacific, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345516538.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.