Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAZZELLA WELDING & FABRICATION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAZZELLA WELDING & FABRICATION INC. in 3114 BETHANY PIKE, WELLSBURG, WV 26070 (NAICS 332312). OSHA activity number 345519722.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mazzella Welding & Fabrication INC. — free Get an email when a new federal OSHA severe-injury report for Mazzella Welding & Fabrication INC. is published. One employer, no account, unsubscribe in one click.
Site address
3114 BETHANY PIKE
City
WELLSBURG
State
WV
ZIP
26070
Mailing
3114 BETHANY PIKE, WELLSBURG, WV 26070
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.243 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 30, 2021
Penalty
Initial $3,316 · Current $2,350 Reduced
29 CFR  1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  (a)  Welding area - On or about 9/8/21, employees were operating a 4.5 inch Makita angle grinder with the guard removed, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $2350
  • — Z (S) $3316

1910.254 D09 III

Serious Gravity 5 1 instance 8 exposed
Issued
Sep 30, 2021
Abate by
Oct 13, 2021
Penalty
Initial $3,901 · Current $2,750 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:  (a) Welding area - On or about 9/8/21, the employer did not replace welding cables with damaged insulation, exposing employees to electrical shocks and burns.
Recent events (2)
  • — I (S) $2750
  • — Z (S) $3901

1910.212 A05

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2021
Abate by
Oct 13, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  (a)  Welding area - On or about 9/8/21, a pedestal mounted floor fan had a guard with openings greater that 1/2 inch in its least dimension, exposing employees to hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mazzella Welding & Fabrication INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345519722.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.