LOCKHART, TX ·
OSHA Inspection: TEED SHIRTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TEED SHIRTS INC in 505 EAST MARKET STREET, LOCKHART, TX 78644 (NAICS 323113). OSHA activity number 345522288.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEED SHIRTS INC
- Site address
- 505 EAST MARKET STREET
- City
- LOCKHART
- State
- TX
- ZIP
- 78644
- Mailing
- 505 EAST MARKET STREET, LOCKHART, TX 78644
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 12
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.22 A03
- Issued
- Dec 14, 2021
- Abate by
- Jan 11, 2022
- Penalty
- Initial $2,340 · Current $936 Reduced
General-duty citation text
29 CFR 1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. On or about September 9, 2021, and at times prior thereto, electrical cords were on the ground in walk ways where employees were performing normal work tasks, exposing employees to a trip and fall hazard.
Recent events (2)
- · I (S) $936
- · Z (S) $2340
1910.303 B08 I
- Issued
- Dec 14, 2021
- Abate by
- Jan 11, 2022
- Penalty
- Initial $4,681 · Current $1,872 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i):Electrical equipment was not firmly secured to the surface on which it was mounted. On or about September 9, 2021, and at times prior thereto, a wired electrical receptacle was not mounted to a surface but instead hanging against a wooden dresser and it was held in place only by the electrical cord that was plugged into it, exposing employees to an electrical hazard.
Recent events (2)
- · I (S) $1872.4
- · Z (S) $4681
1910.305 J02 I
- Issued
- Dec 14, 2021
- Abate by
- Dec 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(i):Receptacles, cord connectors and attachment plugs were not constructed so that they would not accept an attachment plug with a different voltage or current rating than that for which the device was intended. On or September 9, 2021, and at times prior thereto, an electric receptacle that was providing power to a microwave was being powered by an extension cord, exposing employees to an electric hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B02 I
- Issued
- Dec 14, 2021
- Abate by
- Jan 11, 2022
- Penalty
- Initial $4,681 · Current $1,872 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. On or about September 9, 2021, and at times prior thereto, employees were working in and around areas that had several 120V electrical receptacles and a junction box with missing face plates, exposing the employees to a electrical shock hazard: a) Three (3) gang receptacle box in the screening area with a two (2) gang cover. b) Electrical outlet cover missing near the Sportsman EX machine. C) Electrical junction box missing cover near the exhaust fan.
Recent events (2)
- · I (S) $1872.4
- · Z (S) $4681
1910.305 G01 IV A
- Issued
- Dec 14, 2021
- Abate by
- Jan 11, 2022
- Penalty
- Initial $3,121 · Current $1,248 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. On or September 9, 2021, and at times prior thereto, employees were operating machines on the production floor and flexible extension cords were used as a permanent power source instead of fixed wiring, exposing employees to an electrical shock hazard.
Recent events (2)
- · I (S) $1248.4
- · Z (S) $3121
1910.1200 E01
- Issued
- Dec 14, 2021
- Abate by
- Jan 11, 2022
- Penalty
- Initial $2,340 · Current $936 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. On or about September 9, 2021, and at times prior thereto, the employer had not developed and implemented a hazard communication program, exposing employees to chemical burn and fire hazards when working with hazardous chemicals.
Recent events (2)
- · I (S) $936
- · Z (S) $2340
More inspections at Teed Shirts INC
View Teed Shirts INC's full OSHA safety record →
More inspections in this industry (NAICS 323113)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345522288.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.