LOCKHART, TX —
OSHA Inspection: TEED SHIRTS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TEED SHIRTS INC in 505 EAST MARKET STREET, LOCKHART, TX 78644 (NAICS 323113). OSHA activity number 345522288.
Where did this inspection happen?
- Establishment
- TEED SHIRTS INC
- Site address
- 505 EAST MARKET STREET
- City
- LOCKHART
- State
- TX
- ZIP
- 78644
- Mailing
- 505 EAST MARKET STREET, LOCKHART, TX 78644
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A03
- Issued
- Abate by
- Penalty
- Initial $2340.00 · Current $936.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(3):29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. On or about September 9, 2021, and at times prior thereto, electrical cords were on the ground in walk ways where employees were performing normal work tasks, exposing employees to a trip and fall hazard.
Recent events (2)
- — I (S) $936
- — Z (S) $2340
1910.303 B08 I
- Issued
- Abate by
- Penalty
- Initial $4681.00 · Current $1872.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i):Electrical equipment was not firmly secured to the surface on which it was mounted. On or about September 9, 2021, and at times prior thereto, a wired electrical receptacle was not mounted to a surface but instead hanging against a wooden dresser and it was held in place only by the electrical cord that was plugged into it, exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $1872.4
- — Z (S) $4681
1910.305 J02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(i):Receptacles, cord connectors and attachment plugs were not constructed so that they would not accept an attachment plug with a different voltage or current rating than that for which the device was intended. On or September 9, 2021, and at times prior thereto, an electric receptacle that was providing power to a microwave was being powered by an extension cord, exposing employees to an electric hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $4681.00 · Current $1872.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. On or about September 9, 2021, and at times prior thereto, employees were working in and around areas that had several 120V electrical receptacles and a junction box with missing face plates, exposing the employees to a electrical shock hazard: a) Three (3) gang receptacle box in the screening area with a two (2) gang cover. b) Electrical outlet cover missing near the Sportsman EX machine. C) Electrical junction box missing cover near the exhaust fan.
Recent events (2)
- — I (S) $1872.4
- — Z (S) $4681
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $3121.00 · Current $1248.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. On or September 9, 2021, and at times prior thereto, employees were operating machines on the production floor and flexible extension cords were used as a permanent power source instead of fixed wiring, exposing employees to an electrical shock hazard.
Recent events (2)
- — I (S) $1248.4
- — Z (S) $3121
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2340.00 · Current $936.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. On or about September 9, 2021, and at times prior thereto, the employer had not developed and implemented a hazard communication program, exposing employees to chemical burn and fire hazards when working with hazardous chemicals.
Recent events (2)
- — I (S) $936
- — Z (S) $2340
More inspections in this industry (NAICS 323113)
CHICAGO, IL—2026-07-08
SOARDIST USA INC. DBA SOARDIST DISPLAYS AND APPAREL
PENNOCK, MN—2026-07-06
111536 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
PENNOCK, MN—2026-07-06
111528 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
NORWALK, CT—2026-07-06
LAX.COM
NORFOLK, VA—2026-07-01
TEGRA GLOBAL
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source