Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: BUREAU OF ALCOHOL, TOBACCO, FIREARMS & EXPLOSIVES - RENTON WAREHOUSE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BUREAU OF ALCOHOL, TOBACCO, FIREARMS & EXPLOSIVES - RENTON WAREHOUSE in 2200 LIND AVE SW, BLDG A, SUITE 100, RENTON, WA 98057 (NAICS 922190). OSHA activity number 345526628.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bureau of Alcohol, Tobacco, Firearms & Explosives - Renton Warehouse for free Get an email when a new federal OSHA severe-injury report for Bureau of Alcohol, Tobacco, Firearms & Explosives - Renton Warehouse is published. One employer, no account, unsubscribe in one click.
Site address
2200 LIND AVE SW, BLDG A, SUITE 100
City
RENTON
State
WA
ZIP
98057
Mailing
1521 1ST AVENUE SOUTH SUITE 600, SEATTLE, WA 98134
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922190
Employees
3
Ownership type
Federal government (D)

8 citations on file for this inspection.

1910.178 Q07

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 7, 2021
Abate by
Oct 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(7):  Industrial trucks were not examined before being placed in service:  a)	Garage Bay;  The Toyota forklift, serial no. 61907, was not examined before each use.
Recent events (1)
  • · Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 7, 2021
Abate by
Oct 27, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  (a)	Fabrication Room;  The Craftsman 12 inch drill press model no 137.219120 was not securely mounted to the work bench to prevent it from tipping over.
Recent events (1)
  • · Z (S) $0

1910.213 S06

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.213(s)(6):Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  a)	 Fabrication Room;  Metal and wood shavings / shards were located around equipment including the Craftsman drill press and Porter Cable band saw.
Recent events (1)
  • · Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.215(a)(4):Grinding machinery was not used with work rest(s) to support offhand grinding work:  (a)	Fabrication Room;  The Craftsman Bench grinder did not have a work rest.
Recent events (1)
  • · Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   (a)	Fabrication Room;  The Craftsman Bench grinder's tongue guard measured approximately 3/8 inch from the grinding stone.
Recent events (1)
  • · Z (S) $0

1910.157 C01

Other-than-serious 2 instances 3 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a)	 Garage Bay;  A treadmill was located in front of an Advantage fire extinguisher, blocking access to the fire extinguisher.   (b)	Fabrication Room;  Green tarps and metal parts were stored in front of and underneath the fire extinguisher, blocking access to the fire extinguisher.
Recent events (1)
  • · Z (O) $0

1910.157 E02

Other-than-serious 3 instances 3 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(2):Portable fire extinguishers were not visually inspected at least monthly:  (a)	Area adjacent to dog handler's cubicle;  The Kiddie fire extinguisher was not visually inspected monthly.   (b)	Fabrication Room;  The ABC fire extinguisher was not visually inspected monthly.   (c)	Garage Bay;  The Advantage fire extinguisher was not visually inspected monthly.
Recent events (1)
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Oct 7, 2021
Abate by
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1)(ii):The required working space around electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a)	 Garage Bay area adjacent to entrance/ exit door;  Breaker panel PNL-1B, PNL-HB, PNL- LA1, and PNL-LA2 had metal jack stands, metal dollies and steel hand trucks stored underneath/ in front of the breaker panels.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345526628.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.