RENTON, WA ·
OSHA Inspection: BUREAU OF ALCOHOL, TOBACCO, FIREARMS & EXPLOSIVES - RENTON WAREHOUSE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BUREAU OF ALCOHOL, TOBACCO, FIREARMS & EXPLOSIVES - RENTON WAREHOUSE in 2200 LIND AVE SW, BLDG A, SUITE 100, RENTON, WA 98057 (NAICS 922190). OSHA activity number 345526628.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 2200 LIND AVE SW, BLDG A, SUITE 100
- City
- RENTON
- State
- WA
- ZIP
- 98057
- Mailing
- 1521 1ST AVENUE SOUTH SUITE 600, SEATTLE, WA 98134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 922190
- Employees
- 3
- Ownership type
- Federal government (D)
Citations
8 citations on file for this inspection.
1910.178 Q07
- Issued
- Oct 7, 2021
- Abate by
- Oct 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) Garage Bay; The Toyota forklift, serial no. 61907, was not examined before each use.
Recent events (1)
- · Z (S) $0
1910.212 B
- Issued
- Oct 7, 2021
- Abate by
- Oct 27, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) Fabrication Room; The Craftsman 12 inch drill press model no 137.219120 was not securely mounted to the work bench to prevent it from tipping over.
Recent events (1)
- · Z (S) $0
1910.213 S06
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(s)(6):Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards: a) Fabrication Room; Metal and wood shavings / shards were located around equipment including the Craftsman drill press and Porter Cable band saw.
Recent events (1)
- · Z (S) $0
1910.215 A04
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4):Grinding machinery was not used with work rest(s) to support offhand grinding work: (a) Fabrication Room; The Craftsman Bench grinder did not have a work rest.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) Fabrication Room; The Craftsman Bench grinder's tongue guard measured approximately 3/8 inch from the grinding stone.
Recent events (1)
- · Z (S) $0
1910.157 C01
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) Garage Bay; A treadmill was located in front of an Advantage fire extinguisher, blocking access to the fire extinguisher. (b) Fabrication Room; Green tarps and metal parts were stored in front of and underneath the fire extinguisher, blocking access to the fire extinguisher.
Recent events (1)
- · Z (O) $0
1910.157 E02
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2):Portable fire extinguishers were not visually inspected at least monthly: (a) Area adjacent to dog handler's cubicle; The Kiddie fire extinguisher was not visually inspected monthly. (b) Fabrication Room; The ABC fire extinguisher was not visually inspected monthly. (c) Garage Bay; The Advantage fire extinguisher was not visually inspected monthly.
Recent events (1)
- · Z (O) $0
1910.303 G01 II
- Issued
- Oct 7, 2021
- Abate by
- Oct 20, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space around electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Garage Bay area adjacent to entrance/ exit door; Breaker panel PNL-1B, PNL-HB, PNL- LA1, and PNL-LA2 had metal jack stands, metal dollies and steel hand trucks stored underneath/ in front of the breaker panels.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 922190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345526628.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.