Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DELTECH MONOMERS OP CO LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DELTECH MONOMERS OP CO LLC in 11911 SCENIC HIGHWAY, BATON ROUGE, LA 70807 (NAICS 325998). OSHA activity number 345528145.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deltech Monomers OP CO LLC — free Get an email when a new federal OSHA severe-injury report for Deltech Monomers OP CO LLC is published. One employer, no account, unsubscribe in one click.
Site address
11911 SCENIC HIGHWAY
City
BATON ROUGE
State
LA
ZIP
70807
Mailing
11911 SCENIC HIGHWAY, BATON ROUGE, LA 70807
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
80
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 13 instances 3 exposed
Issued
Oct 7, 2021
Abate by
Oct 27, 2021
Penalty
Initial $9,557 · Current $9,557
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about September 11, 2021 employees performed Lockout/ Tag out at the AT-513 Condensate Stripper  without procedural steps being developed.
Recent events (1)
  • — Z (S) $9557

1910.147 C06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 7, 2021
Abate by
Oct 25, 2021
Penalty
Initial $9,557 · Current $9,557
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about September 12, 2021 at Deltech Monomers OpCo, LLC a periodic inspection of energy control procedures was not conducted. This condition exposed employees to hazardous energies such as but not limited to: electrical, hydraulic, gravity, compressed air and thermal.
Recent events (1)
  • — Z (S) $9557

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 7, 2021
Abate by
Oct 25, 2021
Penalty
Initial $9,557 · Current $9,557
29 CFR  1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:   On or about September 12, 2021 at Deltech Monomer OpCo, LLC authorized employee(s) did not receive Lockout/Tagout training  for the purpose and function of energy control  procedures.