Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEST INFRASTRUCTURE CONSTRUCTION, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of WEST INFRASTRUCTURE CONSTRUCTION, LLC in 2836 CLOVIS ROAD, LUBBOCK, TX 79415 (NAICS 237310). OSHA activity number 345531628.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch West Infrastructure Construction, LLC — free Get an email when a new federal OSHA severe-injury report for West Infrastructure Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2836 CLOVIS ROAD
City
LUBBOCK
State
TX
ZIP
79415
Mailing
2836 CLOVIS ROAD, LUBBOCK, TX 79415
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
134
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 23, 2022
Abate by
Mar 23, 2022
Penalty
Initial $13,052 · Current $9,700 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:   On or about September 15, 2021, at 2836, Clovis Road, Lubbock, Texas, employees were exposed to caught in hazards as the employer failed to ensure specific lock out tag out procedures were developed, documented and utilized.
Recent events (2)
  • — I (S) $9700
  • — Z (S) $13052

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 23, 2022
Abate by
Mar 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(3):  Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  On or about September 15, 2021, at 2836, Clovis Road, Lubbock, Texas, employees were exposed to caught in hazards as the employer failed to ensure that all  energy isolating devices were applied to isolate the machine or equipment from the energy source(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C03

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 23, 2022
Abate by
Mar 23, 2022
Penalty
Initial $5,594 · Current $4,000 Reduced
29 CFR  1910.243(c)(3):   Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:   On or about September 15, 2021, at 2836, Clovis Road, Lubbock, employer did not ensure that the hand held right angle grinder was equipped with guards, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5594

1910.334 A02 I

Other-than-serious 1 instance 4 exposed
Issued
Feb 23, 2022
Abate by
Mar 23, 2022
Penalty
Initial $1,047 · Current $0 Reduced
29 CFR  1910.334(a)(2)(i):  Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).   On or about September 15, 2021, at 2836, Clovis Road, Lubbock, Texas, the employer failed to ensure damaged electrical cords were inspected or removed from service, exposing employees to shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1047

1910.334 A03 II

Other-than-serious 1 instance 4 exposed
Issued
Feb 23, 2022
Abate by
Mar 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(3)(ii):  Attachment plugs and receptacles may not be connected or altered in a manner which would prevent proper continuity of the equipment grounding conductor at the point where plugs are attached to receptacles. Additionally, these devices may not be altered to allow the grounding pole of a plug to be inserted into slots intended for connection to the current-carrying conductors:  On or about September 15, 2021, at 2836, Clovis Road, Lubbock, Texas and at times prior to, the employer failed to ensure the grounding conductors were in the electrical cords exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View West Infrastructure Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345531628.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.