OSHA Inspection: GARAGE DOOR PLUS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of GARAGE DOOR PLUS, INC. in 9305 COUNTY RD. 1, CHESAPEAKE, OH 45619 (NAICS 238350). OSHA activity number 345542500.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garage Door Plus, INC. — free Get an email when a new federal OSHA severe-injury report for Garage Door Plus, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9305 COUNTY RD. 1
City
CHESAPEAKE
State
OH
ZIP
45619
Mailing
804 SOLIDA ROAD, SOUTH POINT, OH 45680
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.304 G05

Deleted Serious Gravity 10 2 instances 5 exposed
Issued
Jan 21, 2022
Abate by
Mar 10, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.  a) On or about September 7, 2021 at Tri-State Storage in Chesapeake Ohio, the employer did not ensure that employees working on equipment such as but not limited to the Viking VK-2 115 volt, rolling gate controller, did not become part of the path to ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $14502

1910.332 C

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 21, 2022
Abate by
Mar 10, 2022
Penalty
Initial $4,351 · Current $2,100 Reduced
29 CFR 1910.332(c):Type of training. The training required by this section shall be of the classroom or on-the-job type. The degree of training provided shall be determined by the risk to the employee.  29 CFR 1910.332(c) TABLE S-4. -- Typical Occupational Categories of Employees Facing a Higher Than Normal Risk of Electrical Accident ________________________________________________________________________  Occupation ________________________________________________________________________ Blue collar supervisors(1) Electrical and electronic engineers(1) Electrical and electronic equipment assemblers(1) Electrical and electronic technicians(1) Electricians Industrial machine operators(1) Material handling equipment operators(1) Mechanics and repairers(1)-WORKING ON GARGAGE AND GATE CONTROLLERS Painters(1) Riggers and roustabouts(1) Stationary engineers(1) Welders ________________________________________________________________________  Footnote(1) Workers in these groups do not need to be trained if their work or the work of those they supervise does not bring them or the employees they supervise close enough to exposed parts of electric circuits operating at 50 volts or more to ground for a hazard to exist. [55 FR 32016, Aug. 6, 1990]  a) On or about September 7, 2021, the employer failed to provide electrical training for employees utilizing electrical testers and who were performing repairs on equipment such as but not limited to the Viking VK-2 gate controller used to operate rolling gates, where employees worked on or near exposed electrical circuits operating at 115 volts or more to ground.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $4351

1910.333 C02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jan 21, 2022
Abate by
Mar 10, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2):"Work on energized equipment." Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools.  a) On or about September 7, 2021, the employer did not ensure that their employees were qualified to safely work on or near energized circuits and were familiar with or provided personal protective equipment and insulated tools when working on items such as but not limited to the 115 volt Viking VK-2 rolling gate controller.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.39 A01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jan 21, 2022
Penalty
Initial $1,865 · Current $0 Reduced
29 CFR 1904.39(a)(1):Basic Requirement. Within eight (8) hours after the death of any employee as a result of a work-related incident, you must report the fatality to the Occupational Safety and Health Administration (OSHA), U.S. Department of Labor.  (a) On or about September 7, 2021, the employer did not report a work-related fatality until September 21, 2021.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1865

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345542500.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.