OSHA Inspection: EVERARDO MARROQUIN DBA MARROQUIN CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EVERARDO MARROQUIN DBA MARROQUIN CONSTRUCTION in 54 WOOD OAKS DR., SOUTH BARRINGTON, IL 60010 (NAICS 238160). OSHA activity number 345542708.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Everardo Marroquin DBA Marroquin Construction — free Get an email when a new federal OSHA severe-injury report for Everardo Marroquin DBA Marroquin Construction is published. One employer, no account, unsubscribe in one click.
Site address
54 WOOD OAKS DR.
City
SOUTH BARRINGTON
State
IL
ZIP
60010
Mailing
4750 S. DAMEN AVE. 1ST FL, CHICAGO, IL 60609
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

9 citations on file for this inspection.

1903.19 C01

Other-than-serious 7 instances 2 exposed
Issued
May 10, 2022
Abate by
Jun 28, 2022
Penalty
Initial $349 · Current $349
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Everardo Marroquin dba Marroquin Construction, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number Item Number Abatement Date  01 01 10/26/2021 01 02a 10/26/2021 01 02b 10/26/2021 01 02c 10/26/2021 01 02d 10/26/2021 01 03a 11/23/2021 01 03b 11/23/2021   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $349

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 20, 2021
Abate by
Oct 26, 2021
Penalty
Initial $2,341 · Current $1,639 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a) On September 22, 2021, an employee was not wearing protective helmets where there was a possible danger of head injury from falling objects.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1638.7
  • — Z (S) $2341

1926.451 G01 III

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2021
Abate by
Oct 26, 2021
Penalty
Initial $4,096 · Current $2,867 Reduced
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board:  a)  On September 22, 2021, an employee engaged in roofing activity was exposed to fall hazards of approximately 17 feet to the ground while working from a crawling board.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2867.2
  • — Z (S) $4096

1926.452 M01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2021
Abate by
Oct 26, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance:  a)  On September 22, 2021, an employee engaged in roofing activity was working from a crawling board that did not extend from the roof peak to the roof eave.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 M02

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2021
Abate by
Oct 26, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability):  a)  On September 22, 2021, an employee engaged in roofing activity was working from a crawling board that was not secured to the roof by the ridge hook.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 20, 2021
Abate by
Oct 26, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On September 22, 2021, employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 17 feet above the ground.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 20, 2021
Abate by
Nov 23, 2021
Penalty
Initial $2,926 · Current $1,994 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a) On or about September 22, 2021, employer did not provide training to each employee in order to recognize hazards associated with working from crawling board and to understand procedures to control or minimize those hazards.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1994.1
  • — Z (S) $2926

1926.503 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 20, 2021
Abate by
Nov 23, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:   a) On or about September 22, 2021, employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D01

Other-than-serious 1 instance 1 exposed
Issued
Oct 20, 2021
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:  a) On September 22, 2021, an employee was exposed to fall hazards while using personal fall arrest system components containing connectors that were not drop forged, pressed or formed steel.   No abatement certification or documentation is required for this item.