Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RENTZ ELECTRIC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RENTZ ELECTRIC in 3231 N LOOP 1604 E, SAN ANTONIO, TX 78247 (NAICS 238210). OSHA activity number 345547723.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rentz Electric — free Get an email when a new federal OSHA severe-injury report for Rentz Electric is published. One employer, no account, unsubscribe in one click.
Establishment
RENTZ ELECTRIC
Site address
3231 N LOOP 1604 E
City
SAN ANTONIO
State
TX
ZIP
78247
Mailing
12026 WARFIELD ST,, SAN ANTONIO, TX 78216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.20 B04

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 26, 2021
Abate by
Jan 18, 2022
Penalty
Initial $4,096 · Current $1,500 Reduced
29 CFR  1926.20(b)(4): The employer failed to permit only those employees qualified by training or experience to operate equipment and machinery:   Commercial Construction site: On or about September 27, 2021, employees were exposed to a fall hazard while working from a JLG Telescopic Boom lift  (Model #660SJ) without fall hazard recognition.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4096

1926.453 B02 V

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 26, 2021
Penalty
Initial $4,096 · Current $1,500 Reduced
29 CFR  1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:   Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e):   Commercial Construction site: On or about September 27, 2021, an employee was exposed to a fall hazard while working from a JLG Telescopic Boom lift  (Model #660SJ) without fall protection.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4096

View Rentz Electric's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345547723.