GROVE CITY, OH —
OSHA Inspection: SHERWIN WILLIAMS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SHERWIN WILLIAMS in 3875 BROOKHAM DRIVE, GROVE CITY, OH 43123 (NAICS 325510). OSHA activity number 345550982.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SHERWIN WILLIAMS
- Site address
- 3875 BROOKHAM DRIVE
- City
- GROVE CITY
- State
- OH
- ZIP
- 43123
- Mailing
- 3875 BROOKHAM DRIVE, GROVE CITY, OH 43123
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 130
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.212 A03 II
- Issued
- Dec 7, 2021
- Penalty
- Initial $75,092 · Current $13,653 Reduced
General-duty citation text
1910.212(a)(3)(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a. On or about September 20, 2021, employees were exposed to machine hazards associated with moving parts during servicing and cleaning of the extruder machine on Line 6. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. Sherwin Williams was previously cited for a Serious violation of this Occupational Safety and Health Standard 1910.147(d), which was contained in OSHA inspection number 1280357, citation number 1, item number 2b and was affirmed as a final order on May 30, 2018, with respect to a workplace located at 711 West Wabash, Effingham, IL 62401.
Recent events (2)
- — I (S) $13653
- — Z (R) $75092
More inspections at Sherwin Williams
View Sherwin Williams's full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345550982.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.