Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUSITE CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FUSITE CORPORATION in 6000 FERNVIEW AVENUE, CINCINNATI, OH 45212 (NAICS 335121). OSHA activity number 345563100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fusite Corporation — free Get an email when a new federal OSHA severe-injury report for Fusite Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
FUSITE CORPORATION
Site address
6000 FERNVIEW AVENUE
City
CINCINNATI
State
OH
ZIP
45212
Mailing
6000 FERNVIEW AVENUE, CINCINNATI, OH 45212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335121
Employees
68
Ownership type
A

5 citations on file for this inspection.

1910.22 D02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2022
Penalty
Initial $10,151 · Current $0 Reduced

Hazardous substances 0790

29 CFR  1910.22(d)(2):  Hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again.  If the correction or repair cannot be made immediately, the hazard must be guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired.  (a)  On or about October 13, 2021, maintenance employees were exposed to the hazards of open plating tanks containing cyanide when they knelt or stood on a wooden scaffold plank laid over the tanks to change the air filters in the gold plating room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2022
Penalty
Initial $0 · Current $0

Hazardous substances 0790

29 CFR  1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.   (a)  The portable ladder used to access the scaffold plank on top of the cyanide tanks was not adequate in that  the ladder was not tall enough to step directly over to the platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2022
Penalty
Initial $10,151 · Current $0 Reduced

Hazardous substances 0790

29 CFR  1910.28(b)(1)(i): (1) Unprotected sides and edges.  (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following:    On or about October 13, 2021, the employer did not provide maintenance employees who were accessing and using a scaffold plank over the opening of cyanide plating tanks with an unprotected edge four feet or greater above the floor with any of the following:  (a)  Guardrail systems; (b)  Safety net systems; or (c)  Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1910.30 A03 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 18, 2022
Abate by
Mar 7, 2022
Penalty
Initial $10,151 · Current $0 Reduced

Hazardous substances 0790

29 CFR  1910.30(a)(3)(i): The  employer must train the employee in the nature of the fall hazards in the work area and how to recognize them.  (a)  The employer did not provide adequate training for maintenance employees in the hazards of accessing and using a scaffold plank over four feet or greater without fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10151

1910.157 C01

Other-than-serious 1 instance 10 exposed
Issued
Jan 18, 2022
Abate by
Jan 28, 2022
Penalty
Initial $692 · Current $692
29 CFR  1910.157(c)(1):The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  (a)  On or about October 6, 2021, the portable fire extinguisher in the smelt department, building 4, was sitting on the floor because the ring  used to hold it on the red pole labeled Fire Extinguisher was broken and lying on the floor beside it.
Recent events (2)
  • — I (O) $692
  • — Z (O) $692

View Fusite Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345563100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.