RHINELANDER, WI —
OSHA Inspection: AIRPRO FAN & BLOWER COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AIRPRO FAN & BLOWER COMPANY in 425 W DAVENPORT ST, RHINELANDER, WI 54501 (NAICS 333413). OSHA activity number 345563241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AIRPRO FAN & BLOWER COMPANY
- Site address
- 425 W DAVENPORT ST
- City
- RHINELANDER
- State
- WI
- ZIP
- 54501
- Mailing
- 425 W DAVENPORT ST, RHINELANDER, WI 54501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333413
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 29, 2021
- Abate by
- Mar 31, 2022
- Penalty
- Initial $10,513 · Current $6,307 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. On or about September 25, 2021, employees working with the Dyna-Bal D40 Balance Table were exposed to machine hazards associated with moving parts when wheels mounted on the rotating shaft of the machine were not guarded to prevent employee exposure to the entanglement and caught-n hazards.
Recent events (2)
- — I (S) $6307
- — Z (S) $10513
1910.219 C02 I
- Issued
- Oct 29, 2021
- Abate by
- Mar 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i):All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. On or about September 25, 2021, employees were exposed to entanglement hazards when the rotating shafts on the Dyna-Bal D40 were not guarded to prevent contact with the rotating parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Oct 29, 2021
- Abate by
- Mar 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. On or about September 25, 2021, employees were exposed to the potential caught-in hazards when the vertical drive belts for the Dyna-Bal D40 were not enclosed to prevent exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Oct 29, 2021
- Abate by
- Mar 31, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3):Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets. On or about September 25, 2021, employees were exposed to the in-running nip points of the chain and sprocket drives on the Sterling Electric motor located on backside of the Dyna-Bal D40 Balance Table.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Oct 29, 2021
- Penalty
- Initial $3,255 · Current $1,953 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii):If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made. On or about October 5, 2021, employees were exposed to potential shock hazards when: a) working with a damaged extension cord that had received a cut to the protective insulation that left the interior wires exposed. The cable had been wrapped in electrical tape but the tape did not prevent the exposure of the wire or provide adequate protection against shock. b) working with a Metabo W11-125 Quick angle grinder whose power cable had been damaged. The cable had been wrapped in electrical tape but the tape did not provide adequate protection against shock.