On , OSHA opened a planned safety inspection of US DEPARTMENT OF DEFENSE, ARMY AND AIR FORCE EXCHANGE SERVICES in BLDG 1510 CHILES AVE, STE 600, FORT CARSON, CO 80913 (NAICS 453998). OSHA activity number 345564306.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch US Department of Defense, Army and AIR Force Exchange Services — free Get an email when a new federal OSHA severe-injury report for US Department of Defense, Army and AIR Force Exchange Services is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 1510 CHILES AVE, STE 600
City
FORT CARSON
State
CO
ZIP
80913
Mailing
BLDG 1510 CHILES AVE, STE 600, FORT CARSON, CO 80913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
496
Ownership type
D

3 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 1 instance 30 exposed
Issued
Dec 9, 2021
Abate by
Dec 29, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge, as required by 29 CFR 1960.8(b):  a) Main Exchange exterior garden area:  On or about October 5, 2021, and at times prior, employees were exposed to evacuation delays while two separate exit discharge gates were secured with secondary latches holding the gates in the closed position after activating the 'panic bar' release mechanism.
Recent events (1)
  • — Z (S) $0

1910.37 B04

Serious Gravity 5 4 instances 100 exposed
Issued
Dec 9, 2021
Abate by
Jan 28, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent, as required by 29 CFR 1960.8(b):  a) Main Store Stock room: On or about October 5, 2021, and at times prior, employees were exposed to excessive evacuation delays due to confusing directional indicators on EXIT signs directed evacuees to walls, shelves, and in circles where no exit door was present.  b) Exterior garden area: On or about October 5, 2021, and at times prior, employees were exposed to excessive evacuation delays due to a confusing directional indicator on EXIT signs attached to an exit discharge gate with an arrow directing evacuees away from an operational exit to another exit approximately 50 feet away.  c) Outdoor Living Department: On or about October 5, 2021, and at times prior, employees were exposed to excessive evacuation delays due to an improperly placed EXIT sign, in that the sign was installed on the interior of the department directing evacuees to more remote exit routes and discharge doors.  d) Main Retail near Outdoor Living Department: On or about October 5, 2021, and at times prior, employees were exposed to excessive evacuation delays due to a missing EXIT sign above the entrance to the Outdoor Living retail area resulting in evacuees traveling greater distances to locate an exit discharge.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 9, 2021
Abate by
Dec 21, 2021
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed, as required by 29 CFR 1960.8(b):  a) Class VI Store: On or about October 5, 2021, and at times prior, employees were exposed to electrical hazards at the AHU-4 breaker panel with an uncovered circuit breaker opening.