Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORTHERN EXTRUSION TOOLING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORTHERN EXTRUSION TOOLING, INC. in 905 WEST 19TH STREET, YANKTON, SD 57078 (NAICS 331221). OSHA activity number 345583215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Northern Extrusion Tooling, INC. — free Get an email when a new federal OSHA severe-injury report for Northern Extrusion Tooling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
905 WEST 19TH STREET
City
YANKTON
State
SD
ZIP
57078
Mailing
905 WEST 19TH STREET, YANKTON, SD 57078
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
40
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 instance 40 exposed
Issued
Jan 18, 2022
Abate by
Feb 11, 2022
Penalty
Initial $3,698 · Current $2,219 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Northern Extrusion Tooling, Inc. at 905 West 19th Street, Yankton, SD 57078:  on or about and at times prior to October 15, 2021 the employer did not ensure that machine specific, step-by-step procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section, including but not limited to the ovens within the heat-treat area.  This condition exposed employees to hazards associated with potential hazards from gas lines not being locked out.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

1910.303 B02

Serious Gravity 1 1 instance 40 exposed
Issued
Jan 18, 2022
Abate by
Feb 11, 2022
Penalty
Initial $3,698 · Current $2,219 Reduced
29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)Northern Extrusion Tooling, Inc. at 905 West 19th Street, Yankton, SD 57078: On or about and at times prior to October 15, 2021, the employer did not ensure that electrical equipment was used according to the listing or labeling instructions.  A Relocatable Power Tap (surge protector) was being used to power a DeWalt Chop saw and additional equipment within the woodworking / pallet building area. This condition exposed employees to electrical shock and fire hazards.
Recent events (2)
  • — I (S) $2218.8
  • — Z (S) $3698

View Northern Extrusion Tooling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345583215.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.