MILTON, PA ·
OSHA Inspection: DB EXCAVATING & CONSTRUCTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DB EXCAVATING & CONSTRUCTION, LLC in 252 SHOWERS ROAD, MILTON, PA 17847 (NAICS 238910). OSHA activity number 345585517.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DB EXCAVATING & CONSTRUCTION, LLC
- Site address
- 252 SHOWERS ROAD
- City
- MILTON
- State
- PA
- ZIP
- 17847
- Mailing
- 14 EAST 4TH STREET, WATSONTOWN, PA 17777
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Mar 3, 2022
- Abate by
- Mar 9, 2022
- Penalty
- Initial $3,108 · Current $2,175 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) 252 Showers Road, Milton, PA 17847 - On or about October 18, 2021, an employee did not have a safe means of egress such as a ladder, when working inside a nine and one half (9 1/2) foot deep trench, exposed to cave-in hazards. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $2174.5
- · Z (S) $3108
1926.652 A01
- Issued
- Mar 3, 2022
- Abate by
- Mar 15, 2022
- Penalty
- Initial $4,351 · Current $3,418 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) 252 Showers Road, Milton, PA 17847 - On or about October 18, 2021, an employee was installing a sewer line within a nine and one half (9 1/2) foot deep trench deep without an adequate protective system to protect the employee from a cave-in. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- · I (S) $3417.5
- · Z (S) $4351
More inspections in this industry (NAICS 238910)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345585517.