KANSAS CITY, KS —
OSHA Inspection: BENNETT TOOL AND DIE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BENNETT TOOL AND DIE LLC in 3150 CHRYSLER ROAD, KANSAS CITY, KS 66115 (NAICS 332119). OSHA activity number 345586663.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BENNETT TOOL AND DIE LLC
- Site address
- 3150 CHRYSLER ROAD
- City
- KANSAS CITY
- State
- KS
- ZIP
- 66115
- Mailing
- 3150 CHRYSLER ROAD, KANSAS CITY, KS 66115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 43
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 14, 2021
- Penalty
- Initial $12,288 · Current $7,373 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At the Tool Room, employees engaged in production activities were exposed to amputation and caught-in hazards in that the Okuma Machinery Works Lathe did not have a chuck guard.
Recent events (2)
- — I (S) $7372.8
- — Z (S) $12288
1910.212 A03 II
- Issued
- Dec 14, 2021
- Penalty
- Initial $10,533 · Current $6,320 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Employees engaged in production activities were exposed to amputation hazards in that the point of operation was not guarded properly in the following instances: 1) Finishing Area: Clausing Drill Press 2) Saw Area: Haman Horizontal Band Saw
Recent events (2)
- — I (S) $6319.8
- — Z (S) $10533
1910.212 A05
- Issued
- Dec 14, 2021
- Penalty
- Initial $5,266 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(5):Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: At the Saw Area, employees engaged in production activities were exposed amputation and laceration hazard in a vertical fan had openings on the blade guard that exceeded 1/2 of an inch.
Recent events (2)
- — I (S) $0
- — Z (S) $5266
1910.215 A04
- Issued
- Dec 14, 2021
- Penalty
- Initial $7,022 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.215(a)(4):Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: In the Welding Area, employees engaged in grinding activities were exposed to struck by hazards in that the work rest for the Craftsman pedestal grinder was not adjusted to one eighth of an inch, and was used with an opening 1/2 inch.
Recent events (2)
- — I (S) $4213.2
- — Z (S) $7022
1910.215 B09
- Issued
- Dec 14, 2021
- Penalty
- Initial $7,022 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: At the Welding Area, employees engaged in grinding activities at the Craftsman Pedestal grinder were exposed to struck-by and caught in hazards in that the tongue guard was adjusted to approximately one inch from the grinding wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $7022
1910.243 C01 II A
- Issued
- Dec 14, 2021
- Penalty
- Initial $10,533 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a):Safety guard(s) for portable abrasive wheel(s) did not cover the spindle end, and flange projections: At the Welding Area, employees engaged in production activities were exposed to struck-by and caught in hazards in that guard was removed on the Dewalt portable grinder.
Recent events (2)
- — I (S) $4213.2
- — Z (S) $10533
1910.252 B02 III
- Issued
- Dec 14, 2021
- Penalty
- Initial $10,533 · Current $4,213 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii):Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: Employees engaged in material handling activities were exposed to radiant energy or light radiation in that welding screens were not provided to adjacent employees.
Recent events (2)
- — I (O) $4213.2
- — Z (S) $10533
1910.253 B04 I
- Issued
- Dec 14, 2021
- Penalty
- Initial $8,778 · Current $5,267 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i):Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire; At the Finishing Area, employees engaged in welding activities were exposed to fire hazards from a improperly stored cylinder of oxygen. The oxygen cylinder was not in use and was stored next to an cylinder of liquefied petroleum gas.
Recent events (2)
- — I (O) $5266.8
- — Z (S) $8778
1910.303 G01
- Issued
- Dec 14, 2021
- Penalty
- Initial $8,778 · Current $3,511 Reduced
General-duty citation text
29 CFR 1910.303(g)(1):Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: In the Laser Cutting Area, employees engaged in production activities were exposed to electrical, and fire hazards in that the service disconnect switches were obstructed by a barrier chain, a vertical fan, and two computer stations.
Recent events (2)
- — I (O) $3511.2
- — Z (S) $8778
1910.334 A02 I
- Issued
- Dec 14, 2021
- Penalty
- Initial $5,266 · Current $2,106 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): At the Production Area, employees engaged in production activities were exposed to electrical and fire hazards in that the ground pin was missing on the Dayton Vertical Fan.
Recent events (2)
- — I (O) $2106.4
- — Z (S) $5266
More inspections at Bennett Tool and DIE LLC
View Bennett Tool and DIE LLC's full OSHA safety record →
More inspections in this industry (NAICS 332119)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345586663.