Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MANZANOS STEEL ERECTORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANZANOS STEEL ERECTORS in 168 S. COLLINS ROAD, SUNNYVALE, TX 75182 (NAICS 238120). OSHA activity number 345591176.

Watch Manzanos Steel Erectors — free Get an email when a new federal OSHA severe-injury report for Manzanos Steel Erectors is published. One employer, no account, unsubscribe in one click.
Site address
168 S. COLLINS ROAD
City
SUNNYVALE
State
TX
ZIP
75182
Mailing
3027 PURINGTON AVE, FORT WORTH, TX 76103
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3511.00 · Current $2107.00 Reduced
29 CFR  1926.100(a):Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  (a)   This violation occurred on or about October 19, 21, at the job-site located at 168 S. Collins Blvd, Sunnyvale, TX; where employees were installing shingles to a new residential single family house and were exposed to head injuries where overhead hazard exists by not wearing hard hats.
Recent events (2)
  • — I (S) $2106.6
  • — Z (S) $3511

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2458.00 Reduced
29 CFR  1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   (a)   This violation occurred on or about October 19, 21, at the job-site located at 168 S. Collins Blvd, Sunnyvale, TX; where employees installing flat pan awnings were exposed to fall hazards.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2458.00 Reduced
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)   This violation occurred on or about October 19, 21, at the job-site located at 168 S. Collins Blvd, Sunnyvale, TX; where employees installing flat pan awnings and were using 16- feet extension ladder that did not extend 3-feet above the landing of the roof. Employees were exposed to a fall hazard.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096