2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ESSENTRA PLASTICS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ESSENTRA PLASTICS, LLC in 2614 MCCLELLAND AVENUE, ERIE, PA 16510 (NAICS 326199). OSHA activity number 345595144.

Watch Essentra Plastics, LLC — free Get an email when a new federal OSHA severe-injury report for Essentra Plastics, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2614 MCCLELLAND AVENUE
City
ERIE
State
PA
ZIP
16510
Mailing
2614 MCCLELLAND AVENUE, ERIE, PA 16510
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
39
Ownership type
A

4 citations on file for this inspection.

1910.147 D04

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $8806.00 · Current $6164.00 Reduced
29 CFR  1910.147(d)(4): A lockout device was not attached to all energy sources:  a.) Essentra Plastics, LLC dba Essentra Components, 2614 McClelland Avenue, Erie, PA:  On or about October 22, 2021 and times prior thereto, employees performed servicing and maintenance on equipment including but not limited to the Dip Mold Lines.  Lockout devices were not attached to Lockout points (i.e. Energy Isolating Devices) following shutdown of equipment and as employees entered the machine area to perform clean-up activities.
Recent events (2)
  • — I (S) $6164.2
  • — Z (S) $8806

1910.147 C04 II

Serious Gravity 5 3 instances 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(4)(ii):Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance with items including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  A.) Essentra Plastics, LLC dba Essentra Components, 2614 McClelland Avenue, Erie, PA:  On or about October 22, 2021 and times prior thereto, employees performed servicing and maintenance on equipment including but not limited to the Dip Mold Lines.  The employer's written energy control procedures did not include a description of the methods or means to ensure, or enforce, compliance with the procedure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6632.00 · Current $4642.00 Reduced
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  a.) Essentra Plastics, LLC dba Essentra Components, 2614 McClelland Avenue, Erie, PA:  On or about October 22, 2021 and times prior thereto, employees performed servicing and maintenance on equipment including but not limited to the Dip Mold Lines.  Temporary staffing employees who entered the machine area to perform clean-up activities had not received lockout/tagout training.
Recent events (2)
  • — I (S) $4642.4
  • — Z (S) $6632

1910.147 E03

Other-than-serious 3 instances 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(e)(3): Specific procedures were not developed, documented and incorporated into the employer's energy control program for removal of a lockout or tagout device under the direction of the employer when the authorized employee who applied the lockout or tagout device is not available to remove it:   A.) Essentra Plastics, LLC dba Essentra Components, 2614 McClelland Avenue, Erie, PA:  On or about October 22, 2021 and times prior thereto, employees performed servicing and maintenance on equipment including but not limited to the Dip Mold Lines.  Written procedures were not developed and implemented for the removal of Lockout devices by someone other than the employee who applied the lockout device.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ESSENTRA PLASTICS, LLC's full OSHA safety record →