Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: URETHANE SYSTEMS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of URETHANE SYSTEMS, INC. in 545 SUTTON PLACE, LONGBOAT KEY, FL 34228 (NAICS 238160). OSHA activity number 345602361.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Urethane Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Urethane Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
545 SUTTON PLACE
City
LONGBOAT KEY
State
FL
ZIP
34228
Mailing
6537 116TH AVE. N., LARGO, FL 33773
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
35
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 9, 2022
Abate by
Apr 4, 2022
Penalty
Initial $10,151 · Current $4,060 Reduced
29 CFR  1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a. On or about October 25, 2021, at 545 Sutton Place, Longboat Key, Florida, employees who were not qualified persons were exposed to electrocution hazards when they were not trained and familiar with work practices such as, but not limited to, handling conductive objects such as an aluminum extension ladder within the Minimum Approach Distance of 10 feet for energized overhead power lines at 7,620-volts.
Recent events (2)
  • — I (S) $4060.4
  • — Z (S) $10151

1926.1060 A

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 9, 2022
Abate by
Apr 4, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a. On or about October 25, 2021, at 545 Sutton Place, Longboat Key, Florida, employees who were exposed to electrocution hazards when they were not trained and familiar with work practices such as, but not limited to, handling conductive objects such as an aluminum extension ladder within the Minimum Approach Distance of 10 feet of/ the Minimum Approach Distance of energized overhead power lines at 7,620-volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 A03

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 9, 2022
Abate by
Apr 4, 2022
Penalty
Initial $14,502 · Current $13,052 Reduced
29 CFR  1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into physical or electrical contact with the electric power circuit.  a. On or about October 25, 2021, at 545 Sutton Place, Longboat Key, Florida, employees were exposed to electrocution hazards when using an aluminum extension ladder to gain access to a rooftop located, near energized overhead power lines at 7,620-volts and the employer did not determine whether the performance of the work could bring the employees or the aluminum ladder into physical or electrical contact with the power lines nor did the employer post and maintain proper warning signs where such energized lines existed.
Recent events (2)
  • — I (S) $13051.8
  • — Z (S) $14502

1926.1053 B12

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 9, 2022
Abate by
Apr 4, 2022
Penalty
Initial $10,151 · Current $4,060 Reduced
29 CFR  1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:    a. On or about October 25, 2021, at 545 Sutton Place, Longboat Key, Florida, employees who were unqualified persons were exposed to electrocution hazards when working from the ground below energized electrical power lines to erect an aluminum extension ladder that did not have nonconductive siderails to gain access to a roof-top and the ladder could contact exposed energized electrical power lines at 7,620-volts.
Recent events (2)
  • — I (S) $4060.4
  • — Z (S) $10151

View Urethane Systems, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345602361.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.