Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INFICON EDC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INFICON EDC, INC. in 9075 COBY ST., OVERLAND PARK, KS 66214 (NAICS 334513). OSHA activity number 345606024.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inficon EDC, INC. — free Get an email when a new federal OSHA severe-injury report for Inficon EDC, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
INFICON EDC, INC.
Site address
9075 COBY ST.
City
OVERLAND PARK
State
KS
ZIP
66214
Mailing
9075 CODY ST., OVERLAND PARK, KS 66214
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334513
Employees
55
Ownership type
A

9 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 1 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $9,557 · Current $5,734 Reduced
29 CFR  1910.212(a)(1):Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:   In the Maintenance Area, employees engaged in production activities were exposed to amputation and caught-in hazards in the following instances:  1.) Grizzly Industrial lathe model # G9732 did not have a hood guard.  2.) Unknown make and model lathe did not have a hood guard.  3.) Johnson Manufacturing horizontal band saw model R did not have a guard.
Recent events (2)
  • — I (S) $5734.2
  • — Z (S) $9557

1910.212 A03 II

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  In the Maintenance Area, employees engaged in maintenance activities were exposed to amputation hazards in the following instances:  1.) Bridgeport Mill Press no point of operation guarding.  2.) Clausing Drill Press no point of operating guarding.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  In the Maintenance Area, employees engaged in maintenance activities at the Clausing Drill Press were exposed to struck-by hazards in that the drill press was not securely anchored to prevent walking or moving.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $5,461 · Current $3,277 Reduced
29 CFR  1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m):  In the Maintenance Area, employee(s) operating the Bridgeport Drill Press were exposed to amputation hazards in that the pulley on top of the machine was not guarded.
Recent events (2)
  • — I (S) $3276.6
  • — Z (S) $5461

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.219(e)(1)(i):Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  In the Maintenance Area, employee(s) operating the Bridgeport Drill Press were exposed to amputation hazards in that the belt on top of the machine was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 15, 2021
Penalty
Initial $6,827 · Current $4,096 Reduced
29 CFR  1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  At Bevel Area Station 8, employees engaged in production activities were exposed to electrical and fire hazards in that an electrical cord at the work station had exposed wires at the connector that were energized.
Recent events (2)
  • — I (S) $4096.2
  • — Z (S) $6827

1910.303 B02

Serious Gravity 1 1 instance 17 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $4,096 · Current $2,458 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  In Clean Room #1, employees engaged in administrative activities were exposed to fire and electrical hazards in that the employer had several multi plugs plugged into other multi plugs that powered 3 fans, 3 vacuum pens, and 2 iPhone chargers.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

1910.305 B01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $4,096 · Current $2,458 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  At Bevel Station #8, employees were exposed to an electrical shock and burn hazards in that a knockout was missing on a ground outlet and exposed energized wires were present.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 15, 2021
Abate by
Jan 12, 2022
Penalty
Initial $4,096 · Current $2,458 Reduced
29 CFR  1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  In Clean Room #1, employees engaged in manufacturing activities were exposed to fire and electrical shock hazards in that flexible cord was used to supply power to devices and machines in lieu of fixed wiring.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

View Inficon EDC, INC.'s full OSHA safety record →