OVERLAND PARK, KS —
OSHA Inspection: INFICON EDC, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INFICON EDC, INC. in 9075 COBY ST., OVERLAND PARK, KS 66214 (NAICS 334513). OSHA activity number 345606024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INFICON EDC, INC.
- Site address
- 9075 COBY ST.
- City
- OVERLAND PARK
- State
- KS
- ZIP
- 66214
- Mailing
- 9075 CODY ST., OVERLAND PARK, KS 66214
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- Employees
- 55
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $9,557 · Current $5,734 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: In the Maintenance Area, employees engaged in production activities were exposed to amputation and caught-in hazards in the following instances: 1.) Grizzly Industrial lathe model # G9732 did not have a hood guard. 2.) Unknown make and model lathe did not have a hood guard. 3.) Johnson Manufacturing horizontal band saw model R did not have a guard.
Recent events (2)
- — I (S) $5734.2
- — Z (S) $9557
1910.212 A03 II
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): In the Maintenance Area, employees engaged in maintenance activities were exposed to amputation hazards in the following instances: 1.) Bridgeport Mill Press no point of operation guarding. 2.) Clausing Drill Press no point of operating guarding.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.212 B
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: In the Maintenance Area, employees engaged in maintenance activities at the Clausing Drill Press were exposed to struck-by hazards in that the drill press was not securely anchored to prevent walking or moving.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.219 D01
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $5,461 · Current $3,277 Reduced
General-duty citation text
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m): In the Maintenance Area, employee(s) operating the Bridgeport Drill Press were exposed to amputation hazards in that the pulley on top of the machine was not guarded.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1910.219 E01 I
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i):Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: In the Maintenance Area, employee(s) operating the Bridgeport Drill Press were exposed to amputation hazards in that the belt on top of the machine was not guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Dec 15, 2021
- Penalty
- Initial $6,827 · Current $4,096 Reduced
General-duty citation text
29 CFR 1910.303(b)(1):Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: At Bevel Area Station 8, employees engaged in production activities were exposed to electrical and fire hazards in that an electrical cord at the work station had exposed wires at the connector that were energized.
Recent events (2)
- — I (S) $4096.2
- — Z (S) $6827
1910.303 B02
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $4,096 · Current $2,458 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: In Clean Room #1, employees engaged in administrative activities were exposed to fire and electrical hazards in that the employer had several multi plugs plugged into other multi plugs that powered 3 fans, 3 vacuum pens, and 2 iPhone chargers.
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1910.305 B01 II
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $4,096 · Current $2,458 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: At Bevel Station #8, employees were exposed to an electrical shock and burn hazards in that a knockout was missing on a ground outlet and exposed energized wires were present.
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1910.305 G01 IV A
- Issued
- Dec 15, 2021
- Abate by
- Jan 12, 2022
- Penalty
- Initial $4,096 · Current $2,458 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: In Clean Room #1, employees engaged in manufacturing activities were exposed to fire and electrical shock hazards in that flexible cord was used to supply power to devices and machines in lieu of fixed wiring.
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
More inspections at Inficon EDC, INC.
View Inficon EDC, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334513)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345606024.